CHAPTER 3: Configuration

S1 Position 8: Carrier-Control Method

Set position 8 of switch S1 to determine whether the carrier is “constantly on” or “controlled by RTS.” In the “controlled by RTS” setting, the Switch can support switched-carrier, multipoint, or hardware flow-control applications.

S1-8

Carrier

Off

Constantly ON (default)

On

Controlled by RTS

3.1.3CONFIGURATION SWITCH “S2”

Use the individual positions on DIP switch S2 to set word length, signaling- rate range, RTS/CTS delay, or 2- or 4-wire operation, as well as to control diagnostic testing. The factory-default settings are summarized in Table 3-2 below.

Table 3-2. Switch S2 Summary

Position

Function

Default Setting

 

 

 

 

 

S2-1

Not Used

N/A

 

 

S2-2

2-Wire/4-Wire

Off

4-Wire

 

 

 

 

 

S2-3

V.52, V.54 Tests

Off

Normal Operation

 

 

 

 

 

S2-4

RTS/CTS Delay

On

7 ms

S2-5

RTS/CTS Delay

On

 

 

 

 

 

 

S2-6

Signaling-Rate Range

On

-2.5 to +1%

 

 

 

 

 

S2-7

Word Length

Off

10 bits

S2-8

Word Length

Off

 

 

 

 

 

 

 

S2 Position 2: 2-Wire vs. 4-Wire Operation

Set position 2 of switch S2 to determine whether the Multi-Function LD Card operates in 2-wire or 4-wire mode.

S2-2

Operation

Off

4-wire (full- or half-duplex) (default)

On

2-wire (half-duplex only)

13

Page 14
Image 14
Black Box ME758C-RJ11 Switch S2 Summary, S1 Position 8 Carrier-Control Method, S2 Position 2 2-Wire vs -Wire Operation