MULTI-FUNCTION LD CARD

The Multi-Function LD Card is wired as a DCE (Data Communications Equipment) device. Therefore, it would normally be connected to a DTE (Data Terminal Equipment) RS-232 device. You might need to run a special cable or use a special adapter if the serial port of the RS-232 device you want to attach is not the same type of connector as the one on your Card. Even if the serial ports on the Card and the DTE are both RJ-45 connectors, you might still need to use a specially pinned cable. Call your supplier for technical support with these issues, or if you want to attach a DCE device to the Card.

4.5 The Modem-to-Modem Line Cables and Connectors

The Multi-Function LD Card’s line port is always the upper port on its interface module. It is a 6-pin RJ-11 connector on the -RJ11 models or an

8-pin RJ-45 connector on the -RJ45 models, pinned for a standard telco-wiring environment, as shown in Table 4-3 and Figure 4-2 on the next page.

The Multi-Function LD Card operates half-duplex over two wires (one twisted pair) or full- or half-duplex over four wires (two twisted pairs). In all applications, the twisted-pair wire must be 26 AWG or thicker, unconditioned, dry, and metallic. Both shielded and unshielded cable yield favorable results.

NOTE

The Multi-Function LD Card can only communicate in a closed data circuit with another Multi-Function LD Card. It will not work with dialup analog circuits, such as those used with standard modems. For further information about acceptable wire grades, refer to the recommendations in the Appendix.

The modem-to-modem cable connection must be specially cross-pinned, as shown in Table 4-3 and Figure 4-2 on the next page. If your cabling includes punchdown blocks, you can easily do the cross-pinning at a punchdown block. If you will be running cable directly between two Multi-Function LD Cards, you can get a custom cable from your supplier as a special quote, or you can use regular straight-through-pinned cable and repin one of the RJ connectors (that is, rearrange the wiring connections between the terminal block and the actual contacts). You might need special crimping tools or new connectors; call your supplier for these items, or for technical support if you have difficulty.

26

Page 27
Image 27
Black Box May-95, ME758C-RJ45, ME759C-RJ45, ME759C-RJ11, ME758C-RJ11 manual Modem-to-Modem Line Cables and Connectors