MULTI-FUNCTION LD CARD

Data Rates —

57.6, 38.4, 28.8, 19.2, 14.4, 9.6, 7.2, 4.8, 3.6, 2.4, or

 

1.2 kbps (user-selectable)

Maximum

 

Distance —

See the maximum distance chart in the Appendix

Isolation —

1500 volts RMS minimum using custom transformers

Surge-Protection

 

Method —

Silicon Avalanche Diodes

Surge-Response

 

Time —

1 ps

Maximum Surge

 

Protection —

600 watts dissipated after 1 ms

User Controls — (2) Front-panel toggle switches: Remote or (local) Analog loopback; 511 or 511/E V.52 diagnostics;

(3)8-position DIP switches on main module:

(1)for data rate, clock source, protocol, and carrier control;

(1)for 2- or 4-wire operation, diagnostics, RTS/CTS delay, signaling-rate range, and word length;

(1)for input impedance, point-to-point or multipoint operation, remote loopback-test initiation, and antistream control;

(3)Frame-ground-connection jumpers on interface module:

To Line Shield, DTE Shield (Protective Ground), and Signal Ground

Indicators —

(11) Front-panel LEDs:

 

(1) each for Power, Test, Error;

 

(2) each for TD, RD, RTS, and CD

Diagnostics —

ITU-TSS V.54 remote digital and local analog

 

loopbacks; ITU-TSS V.52 BERT testing

Connectors —

On main module:

 

All models:

6

Page 7
Image 7