MULTI-FUNCTION LD CARD

S2 Position 3: V.52 and V.54 Diagnostic Testing

To reset the V.54 circuit, turn switch S2 position 3 ON, then back OFF.

S2-3

Test Mode

Off

Normal Operation (default)

On

Test Disabled

S2 Positions 4 and 5: RTS/CTS Delay

Set positions 4 and 5 of switch S2 to determine the amount of time the Multi- Function LD Card waits after it “sees” RTS before it sends CTS. Possible settings are no delay, 7 ms, or 53 ms.

S2-4

S2-5

RTS/CTS Delay

On

On

7 ms (default)

On

Off

53 ms

Off

On

No delay

Off

Off

No delay

S2-6: Signaling-Rate Range

Set position 6 of switch S2 to determine the degree of asynchronous data-rate fluctuation that the Multi-Function LD Card will accept (that is, how much variance from a given frequency level the Card will tolerate).

S2-6

Signaling-Rate Range

Off

-2.5% to +1% (default)

On

-2.5% to +2.3%

S2-7 and S2-8: Word Length

Set positions 7 and 8 of switch S2 to determine the word length that the Multi- Function LD Card will expect for synchronous or asynchronous data. For example, if you are using the most common data format (1 start bit,

8 data bits, 1 stop bit, and no parity), you would use the factory-default word- length setting (10 bits).

S2-7

S2-8

Word Length

On

Off

8 bits

On

On

9 bits

Off

Off

10 bits (default)

Off

On

11 bits

14

Page 15
Image 15