MULTI-FUNCTION LD CARD
S2 Position 3: V.52 and V.54 Diagnostic Testing
To reset the V.54 circuit, turn switch S2 position 3 ON, then back OFF.
Test Mode | |
Off | Normal Operation (default) |
On | Test Disabled |
S2 Positions 4 and 5: RTS/CTS Delay
Set positions 4 and 5 of switch S2 to determine the amount of time the Multi- Function LD Card waits after it “sees” RTS before it sends CTS. Possible settings are no delay, 7 ms, or 53 ms.
RTS/CTS Delay | ||
On | On | 7 ms (default) |
On | Off | 53 ms |
Off | On | No delay |
Off | Off | No delay |
S2-6: Signaling-Rate Range
Set position 6 of switch S2 to determine the degree of asynchronous
Off | |
On |
S2-7 and S2-8: Word Length
Set positions 7 and 8 of switch S2 to determine the word length that the Multi- Function LD Card will expect for synchronous or asynchronous data. For example, if you are using the most common data format (1 start bit,
8 data bits, 1 stop bit, and no parity), you would use the
Word Length | ||
On | Off | 8 bits |
On | On | 9 bits |
Off | Off | 10 bits (default) |
Off | On | 11 bits |