Bloomfield WFAE-55F Features & Operating Controls, Power Switch, Fryer-Off-Filter, Timer

Models: WFAE-55FS WFAE-55F

1 36
Download 36 pages 57.44 Kb
Page 4
Image 4
Fig. 1 WFAE-55F Features & Operating Controls

UPPER CONTROL PANEL

FRONT VIEW

 

BACK VIEW

 

 

 

 

 

 

 

 

 

 

 

1

FRYER

OFF

FILTER

5

6 POWER SWITCH

B

U

Z

7Z

E

R

2 3 4

POWER HEAT COOK

15

16

 

17

 

14

 

12

 

LOWER CONTROL PANEL

 

FILTER

 

THERMOSTAT

 

 

325

 

ON

 

300

 

 

350

 

 

HI-LIMIT

275

 

 

 

375

 

 

RESET

250

8

OFF

 

 

 

CAUTION

 

 

 

 

 

 

FRYER MUST BE OFF

 

ºF

 

BEFORE USING FILTER

 

 

9

10

 

Fig. 1 WFAE-55F Features & Operating Controls

18

11

13

 

 

FRYER position energizes the FRYER and POWER LIGHT;

 

 

de-energizes FILTER PUMP. HEATING ELEMENTS energized

1

POWER SWITCH

and regulate to setting on CONTROL THERMOSTAT (8).

 

 

 

OFF position de-energized FRYER and FILTER PUMP.

 

(FRYER-OFF-FILTER)

 

 

FILTER position de-energizes FRYER; energizes FILTER PUMP

 

 

SWITCH (6).

2

POWER LIGHT (amber)

Glows to indicate FRYER is energized.

 

 

 

 

 

Glows to indicate HEATING ELEMENT energized;

3

HEAT LIGHT (amber)

Off when oil temperature reaches setting on CONTROL

 

 

THERMOSTAT (8).

4

COOK LIGHT (amber)

Glows to indicate COOK LEVER in cook position.

 

 

 

5

TIMER

Controls LIFT CRADLE AND BUZZER. Start TIMER by pressing

 

 

red button at center of knob. Lift CRADLE will lower. Pointer

 

 

indicates time remaining. When time reaches “0” BUZZER

 

 

sounds and LIFT CRADLE raises.

 

 

 

6

BUZZER LIGHT (amber)

When lit, indicates BUZZER SWITCH (item 7) is turned ON and

BUZZER CIRCUIT is active

 

 

7

BUZZER SWITCH

Activates BUZZER CIRCUIT. When ON will sound BUZZER

 

 

anytime TIMER is at “0”. Turn switch OFF or activate timer to

 

 

silence buzzer.

 

 

ON position energizes FILTER PUMP and causes oil in

 

FILTER PUMP SWITCH

RESERVOIR (10) to be pumped back into frypot.

8

OFF position de-energizes FILTER PUMP.

(ON-OFF)

 

NOTE: POWER SWITCH (1) must be in FILTER position for

 

 

 

 

FILTER PUMP to operate.

 

 

 

 

 

 

 

 

 

 

 

 

2

 

363 300007 OpManual for WFAE-50F/FS Electric Fryer

Page 4
Image 4
Bloomfield WFAE-55F Features & Operating Controls, Power Switch, Fryer-Off-Filter, POWER LIGHT amber, HEAT LIGHT amber