C.PROBLEM: FILTER PUMP WILL NOT RUN

C.PROBLEM: FILTER PUMP WILL NOT RUN

1.Verify that the POWER SWITCH (item 1, upper control panel) is in the FILTER position, and that the FILTER PUMP SWITCH (item 6, lower control panel) is in the ON position.

2.Press the red RESET button (item 9) on the FILTER PUMP MOTOR, accessible on the back of the fryer. If the pump motor continues to trip out, or if no other cause is apparent for the pump’s failure to run, contact a Wells Mfg. Authorized Service Agency for repairs.

D.PROBLEM: FILTER RESERVOIR OVERFLOWS DURING FILTER CYCLE

D.PROBLEM: FILTER RESERVOIR OVERFLOWS DURING FILTER CYCLEBURN HAZARD / HOT OIL SPLASH / SPLATTER CAUTION:

BURN HAZARD / HOT OIL SPLASH / SPLATTER

PROTECTIVE CLOTHING AND GLOVES MUST BE WORN

WHENEVER SERVICING THE FILTER DURING THE FILTERING

CYCLE

Hot oil may splatter, which could result in serious injury.

1.The oil level in the reservoir must be constantly monitored during the filter cycle, and the flow controlled by means of the DRAIN VALVE LEVER (item 11).

2.The surface of the FILTER PAPER may become clogged with crumbs or other debris. If this happens, turn OFF the DRAIN VALVE LEVER (item 11); when bubbles begin appearing in the oil returned to the FRYPOT, turn OFF the FILTER PUMP SWITCH (item 6).

Carefully slide the FILTER RESERVOIR out approximately 6”. Gently run the end of the WOOD CLEANOUT DOWEL across the surface of the FILTER PAPER and scrape the crumbs toward the edges. Carefully slide the FILTER RESERVOIR back into place, making sure the SUCTION TUBE is properly seated in the RECEPTACLE.

Resume filtering, but remember to replace the FILTER PAPER before the next filtering cycle.

E.PROBLEM: FILTER PUMP WON’T PUMP, or PUMPS AIR DURING FILTERING

BUBBLES in the oil while filtering, and/or a failure of the pump to achieve or maintain prime indicate that air is entering the suction side of the pump.

1.Examine the SUCTION TUBE O-RING. A damaged or improperly seated O-RING can cause the FILTER PUMP to lose suction. This will result in a failure to filter the oil, and in a failure of the oil to be returned to the FRYPOT.

Replace SUCTION TUBE O-RING if it is missing, cracked, distorted or scuffed with one of the spare O-rings.

2.Verify that he SUCTION TUBE is fully seated in the SUCTION LINE RECEPTACLE.

3.Internal component damage. Contact a Wells Mfg. Authorized Service Agency.