C.EQUIPMENT SET-UP

C.EQUIPMENT SET-UP

1.Setup the FRYER only on a firm, level, non-combustable surface. Verify local codes for requirements. Concrete, tile, terrazzo or metal surfaces are recommended. Metal over combustible material may not meet code for non-combustible surfaces.

2.LEVELING: Verify that the fryer sits firmly ON BOTH CASTERS AND ON BOTH LEGS. With a spirit level, check that the fryer is level front-to-back and side-to-side. With the adjustable legs, adjust as required to level the fryer.

D.ELECTRICAL INSTALLATION

DANGER

ELECTRICAL SHOCK HAZARD

ELECTRICAL CONNECTIONS MUST BE MADE BY A LICENSED

ELECTRICIAN

Electrical shock will cause death or serious injury.

1.Refer to the nameplate on the front of the fryer. Verify the ELECTRICAL SERVICE POWER. Voltage and phase must match the nameplate specifications, and available electrical service amperage must meet or exceed the specifications listed on page 1.

Wiring must be no less than12 ga. solid copper wire, rated for at least 75ºC.

NOTE: Wire gauge, insulation type and temperature rating , as well as type, size and construction of conduit, must meet or exceed applicable specifications of local codes and of the National Electrical Code.

2.Fryers are shipped from the factory wired for 3Ø electrical service. Refer to theThree-Phase Wiring Diagram included with this fryer, and verify that field wiring conforms to this diagram .

NOTE: FRYERS are FIELD CONVERTIBLE to 1Ø. If single-phase operation is required, refer to the 3-phase to 1-phase Instructions included with the FRYER, and verify that both internal wiring and field wiring conform to the included single-phase wiring diagram .

IMPORTANT: Field wiring must be routed and secured away from the FRYPOT, TUBING and FILTER PUMP AND MOTOR.

NOTE: Field wiring must allow access to the rear of the FRYER for cleaning and for access to the oil filter pump motor RESET BUTTON.

FILTER

FRYPOT

PUMP &

MOTOR

 

 

90º

POWER

CONDUIT

CORD

FITTING

6