Bloomfield WFPE-30F manual Troubleshooting, A. Problem Fryer Will Not Heat

Models: WFPE-30F

1 22
Download 22 pages 45.05 Kb
Page 19
Image 19
TROUBLESHOOTING

TROUBLESHOOTING

A.PROBLEM: FRYER WILL NOT HEAT

1.If: POWER LIGHT (item 2 ) NOT ON. Check the SERVICE POWER BREAKER. Reset if TRIPPED. If breaker continues to trip, contact a licensed electrician to repair field wiring (if that is the cause), or contact a Wells Mfg. Authorized Service Agency for repairs.

2.If: POWER LIGHT (item 2 ) NOT ON. Check the HI-LIMIT THERMOSTAT (item 7). Reset by pressing the HI LIMIT RESET button on the LOWER CONTROL PANEL until it “clicks”.

CAUTION: FIRE HAZARD / HOT OIL

A.PROBLEM: FRYER WILL NOT HEAT THE HI-LIMIT THERMOSTAT IS A FIRE PROTECTION DEVICE. If tripping persists, clean debris from the space between the

hi-limit bulb and the element to enhance oil flow and facilitate reset. Otherwise, contact your authorized Wells service agency for repairs.

DO NOT ATTEMPT TO BYPASS OR HOLD IN THE BUTTON OF THE

HI-LIMIT THERMOSTAT. A FIRE MAY RESULT.

3.If: POWER LIGHT (item 2 ) ON / HEAT LIGHT (item 3) NOTON. Check setting of TEMPERATURE CONTROL THERMOSTAT (item 8). If turning the thermostat fully clockwise (i.e. to a higher temperature )does not turn the HEAT LIGHT ON, and also cause the oil to heat, or if the CONTROL THERMOSTAT calibration is significantly incorrect, contact a Wells Mfg. Authorized Service Agency for repairs.

4.If: POWER LIGHT (item 2 )ON / HEAT LIGHT (item 3) ON. Probable cause is a damaged internal component. Contact a Wells Mfg. Authorized Service Agency for repairs.

B.PROBLEM: FRYER HEATS BUT WILL NOT BUILD PRESSURE or

FRYER WILL NOT MAINTAIN PRESSURE:

1.Your Wells Pressure Fryer builds pressure as the water content of the product being cooked is turned to steam. Small quantities of product being cooked, or product with minimal water content may not contain enough water to build full pressure.

2.Be sure to turn the CONTROL HANDLE (item 14) and COOK LEVER (item 13) both fully counter-clockwise. Observe as the lid lowers into the frypot. Ensure that it lowers smoothly, and that you can feel the handle enter the detent.

3.Examine the red rubber O-RING around the edge of the LID for damage. Replace O-RING (see page 5, item 8.) if required.

4.The CONTROL ROD may be damaged or misadjusted, or some component in the pressure/ exhaust system may be damaged. It is even possible that the PRESSURE GAUGE (item 15) is damaged or inaccurate. Contact a Wells Mfg. Authorized Service Agency for repairs.

17

Page 19
Image 19
Bloomfield WFPE-30F Troubleshooting, A. Problem Fryer Will Not Heat, B. PROBLEM FRYER HEATS BUT WILL NOT BUILD PRESSURE or