TROUBLESHOOTING
A.PROBLEM: FRYER WILL NOT HEAT
1.If: POWER LIGHT (item 2 ) NOT ON. Check the SERVICE POWER BREAKER. Reset if TRIPPED. If breaker continues to trip, contact a licensed electrician to repair field wiring (if that is the cause), or contact a Wells Mfg. Authorized Service Agency for repairs.
2.If: POWER LIGHT (item 2 ) NOT ON. Check the
CAUTION: FIRE HAZARD / HOT OIL
THE
DO NOT ATTEMPT TO BYPASS OR HOLD IN THE BUTTON OF THE
3.If: POWER LIGHT (item 2 ) ON / HEAT LIGHT (item 3) NOTON. Check setting of TEMPERATURE CONTROL THERMOSTAT (item 8). If turning the thermostat fully clockwise (i.e. to a higher temperature )does not turn the HEAT LIGHT ON, and also cause the oil to heat, or if the CONTROL THERMOSTAT calibration is significantly incorrect, contact a Wells Mfg. Authorized Service Agency for repairs.
4.If: POWER LIGHT (item 2 )ON / HEAT LIGHT (item 3) ON. Probable cause is a damaged internal component. Contact a Wells Mfg. Authorized Service Agency for repairs.
B.PROBLEM: FRYER HEATS BUT WILL NOT BUILD PRESSURE or
FRYER WILL NOT MAINTAIN PRESSURE:
1.Your Wells Pressure Fryer builds pressure as the water content of the product being cooked is turned to steam. Small quantities of product being cooked, or product with minimal water content may not contain enough water to build full pressure.
2.Be sure to turn the CONTROL HANDLE (item 14) and COOK LEVER (item 13) both fully
3.Examine the red rubber
4.The CONTROL ROD may be damaged or misadjusted, or some component in the pressure/ exhaust system may be damaged. It is even possible that the PRESSURE GAUGE (item 15) is damaged or inaccurate. Contact a Wells Mfg. Authorized Service Agency for repairs.
17