DVAS  Instruction Manual  System Menu

DVAS Instruction Manual System Menu

EN 31

 

 

9SYSTEM MENU

The System Menu page permits access to the pages that define the DVAS Series disk array connection to the network.

9.1SCSI Settings

Quick Configuration automatically configures these settings.

Refer to the applicable DVR manual for recommended SCSI settings.

Use this page to alter the behavior of the SCSI Host Channels.

Figure 38 Configuring SCSI

SCSI ID

Allows alteration of the SCSI ID of the DVAS array. For most operating systems, the default SCSI ID of

0 is fine. All SCSI IDs on a bus must be different, so ensure that the selected ID does not conflict with another device ID on the bus. Use the pull down menu to choose the desired ID.

Termination

By default, termination is set to AUTOMATIC, to automatically determine whether termination is required.

SCSI Max Transfer Rate

Defines the maximum speed of the SCSI bus. The default setting is Ultra2. Click Save Settings to save these settings.

To apply the new Network and SCSI setting, cycle power to the unit.

9.2Network Settings

The Net Settings tab permits alteration of the properties of the DVAS Series disk array’s network connection. Enter any new settings into the text boxes on the right- hand side of the page, then click Save Configuration to apply them.

Figure 39 Configuring Network Settings

How to Set IP Address

Use the radio buttons to select either DHCP (Dynamic Host Configuration Protocol), or to manually set IP address. If DHCP is chosen, no further values are required.

IP Address

If manually setting up the network, enter a free IP address into the text box. The current IP address may be acceptable.

Subnet Mask

Set the subnet mask that fits your network class. In most cases, 255.255.255.0 is fine. Enter the new subnet mask into the text box.

Gateway

Enter the IP address of your Internet gateway into this text box.

Primary/Secondary DNS

Enter the IP address of both your Primary and Secondary DNS into the text boxes.

Web Page Auto Refresh

Identifies whether the web pages should be reloaded at a selected interval to show any system changes on- screen. Check Enabled to use this function and specify a value (in seconds) for frequency of web page refreshing.

When all settings have been updated, click Save Configuration. Restart the system so the changes take effect.