Image 11
3.2RAID Controller

DVAS Series Instruction Manual Physical Components

EN 11

 

 

3.2RAID Controller

3.2.1 Insertion

A RAID controller should not be inserted while the unit is powered on. Shut down before replacing a faulty RAID controller.

Insert the RAID controller into its slot, lining up the metal runners with the internal guides. Firmly push the RAID controller fully into the chassis until the side clips click into place.

3.2.2 Removal

Power down before removing a faulty controller.

Push the controller side clips inward (towards each other). While supporting the weight of the unit, use the handles to pull the controller free from the unit.

3.3Hard Drive Assemblies

3.3.1 Insertion

Align the disk carrier with an available disk slot. Ensure that the handle is open and the carrier push button is toward the bottom of the chassis. Push the disk carrier until fully inserted, then close the handle and push in the carrier button to secure the chassis in place.

3.3.2 Removal

Do not remove a disk while in operation within a RAID set, as this will cause the RAID set to degrade. Only remove a disk marked as bad by the GUI and having an amber LED illuminated beneath it. To remove a disk, push the button on the disk carrier, releasing the handle. Gently pull the bottom of the handle toward you and wait for ten seconds for the disk to stop spinning, then continue sliding the disk out of the chassis.

Disk drives are sensitive to static electricity and physical shock. Observe proper ESD precautions and handle with care.