DVAS Instruction Manual TroubleshootingEN 39
Start-up Problems
| Problem | Solution | |
|
|
| |
| The system beeps at power | • Beeping does not mean that the unit is broken. If | |
| up. |
| the problem. |
|
| • Current problems can also be found via the GUI interface; click the red X in top | |
|
|
| lights on the unit. |
|
|
| |
| LED/Icon | Indication | |
|
|
|
|
| Power Icon | • | Normally Green. |
|
| • If Red, verify that both power supplies have power, and are switched on. If a power supply has failed, the LED on the power | |
|
|
| supply will not be illuminated, although the blower should still be powered from the surviving power supply. |
| Fan LED | • | Normally Green. |
|
| • If Red, one or more blowers have failed. There are two blowers in the rear of the unit. The two power supplies have embedded | |
|
|
| blowers. It is possible for the blower to fail, and the power supply continues to work. This will not be apparent by looking at the |
|
|
| LED. You can Determine if the blower has failed via the web GUI. |
| Exclaimation Mark LED | • | Normally Green. |
|
| • If Red, the RAID controller has failed, or has a problem. This does not necessarily mean that the controller must be replaced. This | |
|
|
| LED may indicate other faults, such as missing disks or battery errors. Use the web interface to discover the exact nature of the |
|
|
| problem. |
| Disk Drive LEDs | • During activity, the Green LED(s) will flicker (on the front panel, corresponding to the disk drive(s). | |
|
| • If a failure occurs, the LED in the shape of an exclamation mark will illuminate in Amber. | |
|
|
|
|
| Resolving Problems |
| |
| The Bosch Interface indicates | • Determine which disk has failed by its Amber exclamation mark on the front LED panel. Extract the faulty disk and insert a | |
| that a disk has failed, and my |
| blanking panel into its slot. |
| data is still online. | • Contact the dealer to obtain a replacement as soon as possible, as the array may be in a critical state. When the replacement | |
|
|
| module arrives, verify that no damage has occurred during transit. Insert the new disk into the empty slot. The DVAS Series disk |
|
|
| array will detect the new disk, and rebuild to it if the array is critical. If you already had a spare disk, the DVAS Series disk array |
|
|
| will assign the new disk as a spare too. |
|
|
| |
| A power supply has failed, but | • Do not remove the faulty power supply! If a power supply fails, the surviving power supply will continue to power the blower in the | |
| the system is still operational. |
| failed power supply. Removing a power supply drastically reduces airflow in the chassis. Contact your dealer regarding a |
|
|
| replacement power supply (ACCPS). Only remove the failed power supply when the replacement arrives. |
|
|
|
|
| The RAID controller has failed. | • | If a RAID controller fails, the data is inaccessible. Your data is safe on the disks until a replacement controller arrives. Data in write |
|
|
| cache will be lost if a controller fails. |
|
| • Leave the controller in place. | |
|
|
|
|
|
|
| Contact your dealer for assistance with other inquiries. |
Bosch Security Systems 20 January 2004