![On a D1260 Keypad:](/images/new-backgrounds/48020/4802021x1.webp)
GV2 Series Control Panels Owner's Manual Supplement
4.Press the [ENT] key to activate the selected walk test function. The keypad shows the number of testable points within the scope of the keypad: ### PTS TO TEST
5.Press the [NEXT] key to see VIEW UNTESTED?
6.Press the [ENT] key to view the untested points. The keypad shows the total number of untested points within the keypad scope: ### PTS UNTESTED.
7.Press the [NEXT] key to view the first point’s name.
8.Press the [ENT] key to view the point’s hardware state. Refer to Table 2.
Table 2: Hardware States of Points
Display Text | Hardware State |
|
|
1PT### NORMAL HW | Normal |
1PT### OPEN HW | Opened |
|
|
1PT### SHORT HW | Shorted |
1PT### MISSNG HW | Missing |
9.Activate the point’s sensor and observe the appropriate state change.
10.Press the [NEXT] key to advance to the next untested point within the scope of the keypad.
11.Repeat steps 8 through 10 until all points are tested.
On a D1260 Keypad:
1.If you use the command sequence, press the keys indicated in the Command Sequence column of Table 1 on page 10 for the necessary walk test. The keypad shows the number of testable points within the scope of the keypad: ### points remain to be tested. Proceed to Step 5.
2.If you use the menu function list, press the [Menu>] soft key in the lower right corner.
3.Press the [Next >] soft key until the Menu Function Name (refer to Table 1 on page 10) appears.
4.Press the corresponding soft key to activate the necessary Walk Test functions.
The keypad shows the number of testable points within the scope of the keypad: ### points remain to be tested.
Bosch Security Systems, Inc. 2/07 | 11 |