3.3.6Recent Closing

GV2 Series Control Panels Owner's Manual Supplement

3.The user does not return to stop Entry Delay. The Entry Delay time expires.

4.The control panel starts the alarm transmission sequence, accompanied by an Exit Error report.

3.3.5Master Arm No Exit Feature (Unvacated Premises)

If a user Master Arms an area and does not leave the premises (no Entry/Exit zones are faulted during the exit time), the control panel’s No Exit feature automatically shifts the Area from Master Armed to Perimeter Armed.

I have this feature.

I do not have this feature.

3.3.6Recent Closing

If an alarm occurs within two min of the expiration of Exit Time, the control panel creates an “alarm-recent closing” event. If the user armed with a passcode, the user number is included in the recent closing report.

Recent Closing events are not created for Fire Alarm events.

3.4User-Caused False Alarms, Disarming the System

3.4.1Entry Time Defaults

The SIA standard requires an Entry Time of between 30 sec and 4 min. The required default is 30 sec. If the system is not disarmed within Entry Time, the control panel creates an Alarm Event.

During the Entry Time, the control panel sounds an Entry Delay Tone (distinct from the alarm tone).

3.4.2Passcode Disarms System (Area)

When the control panel is in Entry Delay, entering a valid passcode disarms the system as soon as the last digit of the passcode is entered. No other keys are required.

When the control panel is in Exit Delay or is armed, entry of a valid Passcode must be followed by an [ENTER] or [ENT] key.