2.4Passcode Follows Scope

GV2 Series Control Panels Owner's Manual Supplement

2.4Passcode Follows Scope

2.4.1Description

The Passcode Follows Scope feature is an optional arming and disarming restriction that can be enabled on keypads with access to multiple areas. When this feature is set to No, the keypad restricts Passcode Arming and Passcode Disarming to the home area of the keypad. When set to Yes, this feature allows users to arm or disarm all the areas to which they and the keypad have access. This feature causes no restrictions to the keypad scope as it pertains to any command or arming method other than Passcode Arming or Passcode Disarming.

I have this feature.

I do not have this feature.

2.4.2Using Passcode Follows Scope

Arming from a keypad with Panel Wide scope and Passcode Follows Scope enabled:

1.Ensure that the keypad shows idle disarmed text.

2.Ensure that you have a valid passcode with the authority to Passcode Arm in all areas.

3.Enter your passcode by pressing the [passcode digits] followed by the [ENTER] key (D1260) or [ENT] key (D1255).

4.The keypad shows ARMING: 12345678 to indicate which areas are ready to enter exit delay and arm.

5.The keypad shows the exit delay countdown.

6.Exit from the premises.

Arming from a keypad with Panel Wide scope and Passcode Follows Scope disabled (default):

1.Ensure that the keypad shows idle disarmed text.

2.Ensure that you have a valid passcode with the authority to Passcode Arm in all areas.

3.Enter your passcode by pressing the [passcode digits] followed by the [ENTER] key (D1260) or [ENT] key (D1255).

4.The keypad shows the exit delay countdown.

5.Exit from the premises.