3.6.3Alarms Acknowledged within the Abort Window

GV2 Series Control Panels Owner's Manual Supplement

3.6.3Alarms Acknowledged within the Abort Window

If the end user acknowledges an alarm within the Abort Window:

The alarm output is silenced.

No alarm, restoral, or cancel reports are sent.

No alarm, restoral, or cancel reports are entered in the control panel event log.

3.6.4At the End of the Alarm Abort Window

If no user acknowledges the alarm within the Alarm Abort Window, the control panel sends the appropriate alarm reports.

3.7Cancel Report and Cancel Window

If a user acknowledges an alarm after the Abort Window expires, but before Bell Time expires, the control panel sends a Cancel Report. The Cancel Window starts when the alarm is sent and stops when the Alarm Bell timer expires or a user acknowledges an alarm.

3.8Duress Alarm

This feature allows any passcode with the Send Duress permission enabled to always send a Duress Alarm event upon entry. The Duress Alarm feature allows an installation to allocate unique passcodes as the main duress passcodes for all users.

Additionally, when the SIA CP-01 compliant Duress Alarm option is enabled, the Passcode +1 and +2 options are disabled.