Applications manual | 11 |
|
|
2.7 Bosch GWH 425 EF
Features:
Electronic ignition and built in power vent Thermal efficiency of 82%
Vents with 4" stainless steel or galvanized vent pipe Specifically designed for horizontal vent terminations Modulating gas valve — ensures temperature stability
Model GWH 425 EF N for natural gas (NG) supply Model GWH 425 EF L for liquid propane (LP) supply
Qualifies for $300 tax credit (LP only)
GWH 425 EF Technical Specifications
Gas input | Natural Gas: | 28,000 - 130,000 Btu/h | |||||
| LP Gas: | 28,000- 125,000 Btu/h | |||||
|
|
|
|
|
| ||
Minimum flow to | 0.5 gallons per minute (GPM) | ||||||
activate |
|
|
|
|
|
|
|
Maximum flow rates | 4.6 gpm @ 45°F rise | ||||||
|
|
|
|
|
| ||
Thermal Efficiency | NG: 80% LP: 82% | ||||||
Dimensions | 29.75" h x 18.25" w x 8.75" d | ||||||
Weight | 44 lbs. |
|
|
|
|
| |
Modulating gas valve | yes |
|
|
|
|
|
|
Ignition | Electronic |
|
|
|
|
| |
|
|
|
|
| |||
GWH 425 EF Installation Specifications |
| ||||||
Gas connection | ½" Male NPT | ||||||
|
|
|
|
|
| ||
Water connections | ½" Male NPT |
| |||||
NG gas pressure | Minimum: 7" W.C. | ||||||
|
| Maximum: 14" W.C. | |||||
|
|
|
|
|
| ||
LP gas pressure | Minimum: 11" W.C. | ||||||
|
| Maximum: 14" W.C. | |||||
|
|
|
|
|
| ||
Electrical supply | 120VAC - plugs in |
| |||||
Venting | 4" stainless steel | ||||||
|
| or 26 gauge galvanized | |||||
|
|
|
|
|
| ||
|
|
|
|
|
| ||
GWH 425 EF Installation Clearances |
|
|
|
|
| ||
Top (A) | 12" |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Front (B) | 4" |
|
|
|
|
|
|
Back | 0" |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Sides | 4" |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Floor (C) | 12" |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Fig. 1 Venting configurations
Installation guidelines:
Venting:
4"
Slope horizontal runs up to termination ¼" per foot. Do not combination vent with any other appliance. See manual for vent terminator clearances.
Gas piping:
Heater will not function properly without adequate supply gas pressure.
Any appliance connector should be ¾" minimum diameter
Plumbing:
Install the included pressure relief valve and pipe to suitable drain.
Minimum piping diameter is ½".
Do not solder directly to connections on the bottom of the unit. Use full port ball valves for isolation valves.
Bosch Water Heating | Applications manual 11.2007 |