2.9 Bosch GWH 425 PN

Features:

Standing pilot ignition

78% thermal efficiency

Endless hot water for one major application at a time

Modulating gas valve — constant temperature at varying flow rates Model GWH 425 PN N for natural gas (NG) supply

Model GWH 425 PN L for liquid propane (LP) supply 15-year warranty

GWH 425 PN Technical Specifications

Power input

Natural Gas: 31,000 - 117,000 BTU

 

 

 

LP Gas: 31,000 - 117,000 BTU

 

 

Minimum flow to activate

0.6 gallons per minute (gpm)

Flow rates

45˚F rise @ 4.2 gpm

 

55˚F rise @ 3.4 gpm

 

65˚F rise @ 2.9 gpm

 

77˚F rise @ 2.4 gpm

 

90˚F rise @ 2.1 gpm

 

 

Thermal Efficiency

NG: 78% LP: 78%

Dimensions

25.75" h x 16.75" w x 8.5" d

Weight

33 lbs.

Modulating gas valve

yes

Ignition

Standing pilot

Accessories

Horizontal vent kit (AQ4) - power

 

vent kit for horizontal venting

 

 

GWH 425 PN Installation Specifications

Gas connection

¾" Male NPT

 

 

Water connections

¾" Male NPT

NG gas pressure

Minimum: 7" W.C.

 

Maximum: 14" W.C.

 

 

LP gas pressure

Minimum: 11" W.C.

 

Maximum: 14" W.C.

 

 

Water pressure

Minimum: 30 PSI

 

Maximum: 150 PSI

 

 

Electrical supply

120VAC - plugs in

Vertical venting

5" minimum diameter - natural

 

draft

 

 

Horizontal venting

AQ4 horizontal vent kit required

 

for horizontal terminations

 

 

GWH 425 PN Installation Clearances

Top (A)

12"

 

 

Front (B)

4"

Back

0"

 

 

Sides

4"

 

 

Floor (C)

12"

 

 

LIS TED VE NT C AP

MINIMUM 6

FE ET (1.8M)

LIS TED G AS VE NT

E S TAB LIS H A ONE

F OOT R IS E B E F OR E

ANY E LB OW S

Fig. 4 Venting configuration

Installation guidelines:

Venting:

5" minimum diameter — do not reduce vent size. Refer to installation manual for vent material options

Do not combination vent with any power vented appliances.

Establish a one-foot rise before any elbows

Minimum vent height - 6 feet.

Horizontal sections must slope upwards at least ¼" for every foot of the horizontal length and be properly supported.

Gas piping:

Heater will not function properly without adequate supply gas pressure.

Any appliance connector should be ¾" minimum diameter

Plumbing:

Install the included pressure relief valve and pipe to suitable drain.

Minimum piping diameter is ¾".

Do not solder directly to the bottom of the unit. Use full port ball valves for isolation valves.