2.3 Bosch GWH C 800 ES

Features:

Electronic ignition and built in power vent Condensing technology with 92% thermal efficiency

Vents vertically or horizontally with 3" or 4" PVC, CPVC or ABS (Schedule 40) vent pipe.

Direct vent room-sealed combustion with concentric venting option

Computerized temperature control — ensures temperature stability Model GWH C 800 ES N for natural gas (NG) supply

Model GWH C 800 ES L for liquid propane (LP) supply 15-year warranty

Qualifies for $300 tax credit

GWH C 800 ES Technical Specifications

Gas input

Natural Gas: 19,900 - 199,000 BTU

 

 

 

 

LP Gas: 19,900 - 199,000 BTU

 

 

 

Minimum flow to activate

0.65 gallons per minute (gpm)

Flow rates

45˚F rise @ 8.0 gpm

 

55˚F rise @ 6.4 gpm

 

65˚F rise @ 5.5 gpm

 

77˚F rise @ 4.6 gpm

 

90˚F rise @ 3.9 gpm

 

 

 

Thermal Efficiency

NG: 92% LP: 92%

Dimensions

30½" h x 17⅞" w x 11¼" d

Weight

74 lbs.

Modulating gas valve

yes

Ignition

Electronic

Accessories

Outdoor kit (PTOK)

 

Wireless Remote (TSTAT2)

 

Tankless Link Cascading Kit (TLINK)

 

Freeze Prevention Kit (8700400022)

 

Water Filter Kit (8703305356)

 

Concentic Termination Kit

 

(BWH60L46)

 

GWH C 800 ES Installation Specifications

 

Gas connection

¾" Male NPT

 

 

 

Water connections

¾" Male NPT

NG gas pressure

Minimum: 4" W.C.

 

Maximum: 14" W.C.

 

 

 

LP gas pressure

Minimum: 9" W.C.

 

Maximum: 14" W.C.

 

 

 

Water pressure

Minimum: 30 PSI

(Static)

Minimum well pressure: 40 PSI

 

Maximum: 150 PSI

 

Electrical supply

120VAC - plugs in

 

Venting

3" or 4" PVC, CPVC, or ABS

 

(Schedule 40) direct vent sealed

 

combustion

 

 

 

GWH C 800 ES Installation Clearances

Top (A)

12"

 

 

Front (B)

1"

Back

0"

 

 

Sides

1"

 

 

Floor (C)

12"

 

 

MAINTAIN 12 IN.

 

(18 IN. FOR CANADA)

VENT

MINIMUM CLEARANCE

ABOVE

 

HIGHEST ANTICIPATED

 

SNOW LEVEL.

COMBUSTION

MAXIMUM OF 24 IN.

AIR

ABOVE ROOF.

 

ROOF BOOT/

 

 

FLASHING (FIELD

 

 

SUPPLIED

 

 

 

 

MINIMUM

 

 

1”

INTAKE

 

 

EXHAUST

INTAKE

VENT

 

 

 

EXHAUST

 

 

COMBUSTION

 

 

AIR

DRAIN TEE

 

DRAIN TEE

 

 

Fig. 1 Venting configurations

Installation guidelines:

Venting:

Must be 3" or 4" PVC, CPVC or ABS (Schedule 40) vent pipe. Attach drain for internal condensate siphon and dispose of according to local codes.

Do not combination vent with any other appliance. Install an external condensate drain where applicable. See manual for vent terminator clearances.

Gas piping:

Heater will not function properly without adequate supply gas pressure.

Any appliance connector should be ¾" minimum diameter

Plumbing:

Install the included pressure relief valve and pipe to suitable drain.

Minimum piping diameter is ¾".

Do not solder directly to the bottom of the unit. Use unions to facilitate easy future maintenance. Use full port ball valves for isolation valves.

Partially fill condensate drain tube loop (where applicable)

Bosch Water Heating

Applications manual 11.2007