Bosch Appliances GWH 260 PN/HN2, GWH 425 PN/HN4GWH 4254 manual GWH 260 PN Installation Clearances

Models: GWH 425 PN/HN4GWH 4254 GWH 260 PN/HN2

1 50
Download 50 pages 25.05 Kb
Page 14
Image 14

1 4

Applications manual

 

 

2.10 Bosch GWH 260 PN

Features:

Standing pilot ignition

78% thermal efficiency

Mounts on wall for easy installation

Venting: 4" double wall B-vent — natural draft

Modulating gas valve — constant temperature at varying flow rates Model GWH 260 PN N for natural gas (NG) supply

Model GWH 260 PN L for liquid propane (LP) supply 15-year warranty

GWH 260 PN Installation Clearances

Top (A)

12"

 

 

Front (B)

4"

Back

0"

 

 

Sides

4"

 

 

Floor (C)

12"

 

 

GWH 260 PN Technical Specifications

Gas input

Natural Gas: 30,735 - 74,900 BTU

 

 

 

LP Gas: 30,735 - 74,900 BTU

 

 

Minimum flow to activate

0.6 gallons per minute (gpm)

Flow rates

45˚F rise @ 2.6 gpm

 

55˚F rise @ 2.1 gpm

 

65˚F rise @ 1.7 gpm

 

77˚F rise @ 1.5 gpm

 

90˚F rise @ 1.3 gpm

 

 

Thermal Efficiency

NG: 78% LP: 78%

Dimensions

28.8" h x 12.2" w x 8.5" d

Weight

25 lbs.

Modulating gas valve

yes

Ignition

Standing pilot

 

GWH 260 PN Installation Specifications

Gas connection

¾" Male NPT

 

 

Water connections

¾" Male NPT

NG gas pressure

Minimum: 7" W.C.

 

Maximum: 14" W.C.

 

 

LP gas pressure

Minimum: 11" W.C.

 

Maximum: 14" W.C.

 

 

Water pressure

Minimum: 30 PSI

(Static)

Minimum well pressure: 40PSI

 

Maximum: 150 PSI

 

 

Electrical supply

120VAC - plugs in

Venting

4" double wall B-vent - natural

 

draft

 

 

LIS TED VE NT C AP

MINIMUM 6

FE ET (1.8M)

LIS TED G AS VE NT

E S TAB LIS H A ONE

F OOT R IS E B E F OR E

ANY E LB OW S

Fig. 4 Venting configuration

Installation guidelines:

Venting:

4" minimum diameter — do not reduce vent size. Refer to installation manual for vent material options

Do not combination vent with any power vented appliances.

Establish a one-foot rise before any elbows

Minimum vent height - 6 feet.

Horizontal sections must slope upwards at least ¼" for every foot of the horizontal length and be properly supported.

Gas piping:

Heater will not function properly without adequate supply gas pressure.

Any appliance connector should be ¾" minimum diameter

Plumbing:

Install the included pressure relief valve and pipe to suitable drain.

Minimum piping diameter is ¾".

Do not solder directly to the bottom of the unit. Use full port ball valves for isolation valves.

Application manual 11.2007

Bosch Water Heating

Page 14
Image 14
Bosch Appliances GWH 260 PN/HN2 manual GWH 260 PN Installation Clearances, GWH 260 PN Technical Specifications