6

2.2 Bosch GWH 715 ES

Features:

Electronic ignition and built in power vent 82% thermal efficiency

Vents vertically or horizontally with 3" or 4" stainless steel (AL29- 4C)

Direct vent room-sealed combustion

Computerized temperature control — ensures temperature stability Model GWH 715 ES N for natural gas (NG) supply

Model GWH 715 ES L for liquid propane (LP) supply 15-year warranty

Qualifies for $300 tax credit

GWH 715 ES Technical Specifications

Gas input

Natural Gas: 19,900 - 199,000 BTU

 

 

 

 

LP Gas: 19,900 - 199,000 BTU

 

 

 

Minimum flow to activate

0.65 gallons per minute (gpm)

Flow rates

45˚F rise @ 7.2 gpm

 

55˚F rise @ 5.9 gpm

 

65˚F rise @ 5.0 gpm

 

77˚F rise @ 4.2 gpm

 

90˚F rise @ 3.6 gpm

 

 

 

Thermal Efficiency

NG: 82% LP: 82%

Dimensions

30½" h x 17⅞" w x 11¼" d

Weight

67 lbs.

Modulating gas valve

yes

Ignition

Electronic

Accessories

Outdoor kit (PTOK)

 

Wireless Remote (TSTAT2)

 

Tankless Link Cascading Kit (TLINK)

 

Freeze Prevention Kit (8700400022)

 

Water Filter Kit (8703305356)

 

 

 

GWH 715 ES Installation Specifications

 

Gas connection

¾" Male NPT

 

 

 

Water connections

¾" Male NPT

 

NG gas pressure

Minimum: 4" W.C.

 

Maximum: 14" W.C.

 

 

 

LP gas pressure

Minimum: 9" W.C.

 

Maximum: 14" W.C.

 

 

 

Water pressure

Minimum: 30 PSI

(Static)

Minimum well pressure: 40 PSI

 

Maximum: 150 PSI

 

Electrical supply

120VAC - plugs in

 

Venting

3" or 4" stainless steel (AL29-4C)

 

direct vent

 

room-sealed combustion

 

 

 

Applications manual

GWH 715 ES Installation Clearances

Top (A)

12"

 

 

Front (B)

1"

Back

0"

 

 

Sides

1"

 

 

Floor (C)

12"

 

 

3ft minimum distance

3ft minimum distance

Fig. 1 Venting configurations

Installation guidelines:

Venting:

Must be 3" or 4" AL29-4C sealed stainless steel vent pipe. Slope horizontal runs up to termination ¼" per foot. The last horizontal section of exhaust vent pipe between last elbow and termination must slope down to the termination ¼" per foot. Do not combination vent with any other appliance.

Install condensate drain where applicable. See manual for vent terminator clearances.

Gas piping:

Heater will not function properly without adequate supply gas pressure.

Any appliance connector should be ¾" minimum diameter

Plumbing:

Install the included pressure relief valve and pipe to suitable drain.

Minimum piping diameter is ¾".

Do not solder directly to the bottom of the unit. Use unions to facilitate easy future maintenance. Use full port ball valves for isolation valves.

Partially fill condensate drain tube loop (where applicable) with water prior to start up.

Application manual 11.2007

Bosch Water Heating

Page 6
Image 6
Bosch Appliances GWH 260 PN/HN2 manual Features, GWH 715 ES Technical Specifications, GWH 715 ES Installation Specifications