1 6 | Applications manual |
|
|
2.12Powerstream Pro RP1P, RP2P, RP3P, RP7P, RP9P,RP12PT
Features:
Installs vertically or horizontally (Model RP12PT only installs horizontally)
All models must be hardwired
Solid copper heat exchanger, copper sheathed elements and tough plastic housing
High/low kW settings possible within most models Model RP12PT has thermostatic adjustable control
Installation guidelines:
Electrical:
Refer to the chart below as specification varies by model
Plumbing:
Do not solder directly to connections on the bottom of the unit. Use unions to facilitate easy future maintenance.
Use full port ball valves for isolation valves.
Technical Specifications
Model Part # | Wire Size | Voltage | Amps | High kW | Low kW |
| Degree rise at flow rates (GPM)* |
| Activation | ||
|
|
|
|
|
| 0.5 | 0.75 | 1.0 | 1.5 | 2.0 | rate (GPM) |
|
|
|
|
|
|
| |||||
RP1P | 8AWG | 240 | 40 | 9.50 | — | — | 84° | 64° | 42° | 32° | 0.75 |
|
|
| 20 | — | 4.75 | — | 42° | 32° | 21° | 16° |
|
RP2P | 10AWG | 277 | 22 | 6.00 | — | 81° | 55° | 42° | 27° | — | 0.50 |
|
|
| 11 | — | 3.00 | 41° | 28° | 21° | 14° | — |
|
RP3P | 10AWG | 120 | 29 | 3.40 | — | 41° | 28° | 20° | — | — | 0.50 |
RP7P | 10AWG | 240 | 30 | 7.20 | — | — | 63° | 48° | 32° | 24° | 0.75 |
|
|
| 15 | — | 3.60 | — | 32° | 24° | 16° | 12° |
|
RP9P | 8AWG | 277 | 35 | 9.50 | — | — | 84° | 64° | 42° | 32° | 0.75 |
|
|
| 18 | — | 4.75 | — | 42° | 32° | 21° | 16° |
|
RP12PT | 6AWG | 240 | 50 | 12.00 | — | — | 90° | 72° | 52° | 42° | 0.75 |
Application manual 11.2007 | Bosch Water Heating |