2.6 Bosch GWH 345 ESR

Features:

Specifically designed for recirculating applications Electronic ignition and built in power vent

GWH 345 ESR thermal efficiency of 82%

Vents vertically or horizontally with 3" stainless steel (AL29-4C) Direct vent room-sealed combustion

Computerized temperature control — ensures temperature stability

Model GWH 345 ESR N for natural gas (NG) supply Model GWH 345 ESR L for liquid propane (LP) supply 10-year warranty

GWH 345 ESR Technical Specifications

Gas input

GWH 345 ESR: 32,000 - 95,000 Btu/h

 

 

Maximum flow rates

GWH 345 ESR: 3.5gpm @ 45°F rise

 

 

Thermal Efficiency

82%

Dimensions

27.5" h x 15.75" w x 11.75" d

Weight

47 lbs.

Modulating gas valve

yes

Ignition

Electronic

GWH 345 ESR Installation Specifications

Gas connection

¾" Male NPT

 

 

 

 

 

Water connections

¾" Male NPT

NG gas pressure

Minimum: 5.5" W.C.

 

 

Maximum: 14" W.C.

 

 

 

 

 

LP gas pressure

Minimum: 11" W.C.

 

 

Maximum: 14" W.C.

 

 

 

 

 

Electrical supply

120VAC - plugs in

Venting

3" stainless steel (AL29-4C)

 

 

direct vent

 

 

room-sealed combustion

 

 

 

 

 

 

 

GWH 450 ESR Installation Clearances

 

 

 

Top (A)

12"

 

 

 

 

 

 

 

 

 

 

Front (B)

1"

 

 

 

 

Back

0"

 

 

 

 

 

 

 

 

 

 

Sides

1"

 

 

 

 

 

 

 

 

 

 

Floor (C)

12"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fig. 1 Venting configurations

Installation guidelines:

Venting:

Must be 3" or 4" AL29-4C sealed stainless steel vent pipe.

Slope horizontal runs up to termination ¼" per foot. The horizon- tal section between last elbow and termination must slope down to the termination ¼" per foot.

Do not combination vent with any other appliance.

Always install an external condensate drain except when termi- nating horizontally with less than 3 feet of pipe.

See manual for vent terminator clearances.

Gas piping:

Heater will not function properly without adequate supply gas pressure.

Any appliance connector should be ¾" minimum diameter

Plumbing:

Install the included pressure relief valve and pipe to suitable drain.

Minimum piping diameter is ¾".

Do not solder directly to the bottom of the unit. Use unions to facilitate easy future maintenance. Use full port ball valves for isolation valves.