8 Applications manual
2.4 Outdoor Installation for GWH 715 ES, | Installation on wood siding |
and GWH C 800 ES |
|
Outdoor Kit (PTOK) installation: |
|
The installation of this outdoor kit (PTOK) is required when |
|
installing either of the above appliances outdoors |
|
Outdoor cap easily retrofits to these indoor models |
|
Outdoor kit comes with Freeze Prevention which must be installed |
|
Exterior water piping should be protected if freezing conditions |
|
could exist |
|
Minimum clearances: |
|
Installation on vinyl siding:
Ref. | Description | Min. | |
distances | |||
|
| ||
A | Directly below or adjacent to |
| |
| an opening; operable | ≥ 4 ft | |
B | |||
windows, doors and any fresh | |||
|
| ||
C | air openings |
| |
|
|
| |
D | From any adjacent wall | ≥ 4 ft | |
|
|
| |
E | Below a gutter, sanitary | ≥ 3 ft | |
pipework, eaves or overhang | |||
|
| ||
|
|
| |
F | Above ground | ≥ 1 ft | |
|
|
| |
G | From a gas meter or gas | ≥ 5 ft | |
regulator | |||
|
| ||
Outdoor Installation Clearances |
| ||
Source: NFPA 54 National Fuel Gas Code |
| ||
| ANSI Z223.1 |
|
Application manual 11.2007 | Bosch Water Heating |