8 Applications manual

2.4 Outdoor Installation for GWH 715 ES,

Installation on wood siding

and GWH C 800 ES

 

Outdoor Kit (PTOK) installation:

 

The installation of this outdoor kit (PTOK) is required when

 

installing either of the above appliances outdoors

 

Outdoor cap easily retrofits to these indoor models

 

Outdoor kit comes with Freeze Prevention which must be installed

 

Exterior water piping should be protected if freezing conditions

 

could exist

 

Minimum clearances:

 

Installation on vinyl siding:

Ref.

Description

Min.

distances

 

 

A

Directly below or adjacent to

 

 

an opening; operable

≥ 4 ft

B

windows, doors and any fresh

 

 

C

air openings

 

 

 

 

D

From any adjacent wall

≥ 4 ft

 

 

 

E

Below a gutter, sanitary

≥ 3 ft

pipework, eaves or overhang

 

 

 

 

 

F

Above ground

≥ 1 ft

 

 

 

G

From a gas meter or gas

≥ 5 ft

regulator

 

 

Outdoor Installation Clearances

 

Source: NFPA 54 National Fuel Gas Code

 

 

ANSI Z223.1

 

Application manual 11.2007

Bosch Water Heating

Page 8
Image 8
Bosch Appliances GWH 260 PN/HN2 manual Outdoor Installation for GWH 715 ES, GWH C 800 ES, Description Min Distances