Applications manual

15

 

 

2.11 Powerstream Pro RP17PT, RP27PT

Features:

Over 90% efficiency rating

10-year warranty on heat exchanger Durable polymer construction External temperature control knob Thermal cut-out for safety

Flow sensor to provide a constant output temperature Provides an ENDLESS supply of hot water

Weighs less than 25 pounds and fits virtually anywhere

No temperature/pressure relief valve necessary (unless required by local codes)

 

 

Technical Specifications

 

Model

RP17PT

RP27PT

Efficiency

90%

94%

Dimensions

15 ½" x 15 ¼" x 4 ½"

15 ½" x 15 ¼" x 4 ½"

 

Weight

20 lbs.

22 lbs.

Water fittings

¾" Male NPT

¾" Male NPT

Activation rate

0.6 gpm

0.8 gpm

Electrical requirements

 

 

Volts

240

240

 

Kilowatts

17.25kW

26.85kW

Amps

U.S.A

80 (2x40 amps)

120 (3x40 amps)

 

Canada

80 (1x80 amps)

120 (1x120amps)

 

 

 

 

Wire

U.S.A

8 AWG

8 AWG

size

 

(4 conductors & ground)

(4 conductors & ground)

 

Canada

Check Canadian

Check Canadian

 

 

Electrical Code

Electrical Code

 

 

(C22.1-02)

(C22.1-02)

 

 

 

 

 

Phase

Single

Single

Maximum flow rate at given temperature rise

45°F Rise

2.6 gpm

4.0 gpm

50°F Rise

2.3 gpm

3.7 gpm

60°F Rise

2.0 gpm

3.0 gpm

70°F Rise

1.7 gpm

2.6 gpm

80°F Rise

1.5 gpm

2.2 gpm

Installation guidelines:

Electrical:

Minimum electrical service for RP17PT is 150 amps. Minimum electrical service for RP27PT is 200 amps. Minimum wire size for both models is 8 AWG.

Plumbing:

Do not solder directly to connections on the bottom of the unit. Use unions to facilitate easy future maintenance.

Use full port ball valves for isolation valves.

RP17PT terminal block

2 independent

40 amp double-pole circuit breakers

Fig. 5 RP17PT Electrical Connections

RP27PT terminal block

3 independent

40 amp double-pole circuit breakers

Fig. 6 RP27PT Electrical Connections

Bosch Water Heating

Applications manual 11.2007

Page 15
Image 15
Bosch Appliances GWH 425 PN/HN4GWH 4254, GWH 260 PN/HN2 manual Technical Specifications, Electrical requirements