High Performance LCD Monitors

TroubleShooting Guide en 45

 

 

8TroubleShooting Guide

Problem

Solution

 

 

No image is

– Check that the power cord of the monitor is securely

displayed on

connected into the wall outlet or grounded extension

screen

cable or strip.

 

– Power switch should be in the ON position and the

 

LED lit.

 

– Check that the Brightness and/or Contrast

 

adjustments of the display have not been turned

 

down to minimum levels.

 

 

“Going to

– The signal cable should be completely connected to

Sleep” message

the video card/computer.

is displayed

– The video card should be completely seated in its slot

 

and the computer switched ON.

 

 

Display image is

– Push the down key to activate the Autoset function.

not centered, is

-or-

too small, or too

– Adjust the Clock and Phase in the PC OSD submenu.

large in the PC

 

mode

 

 

 

Monitor does

Compare the Trigger Option setting on the Trigger menu

not switch upon

with the physical alarm output setting for alarm device.

trigger input

 

 

 

Monitor does

If the video input and the Trigger Input are from the same

not sound the

source:

buzzer

– Set the Trigger Time to zero (0).

 

If the video input and the Trigger Input are from different

 

sources, check the following settings on the Picture/

 

Sound menu:

 

– Ensure that the Mute option is set to OFF.

 

– Ensure that the Volume is set to an audible level.

 

 

Bosch Security Systems, Inc.

Installation Manual

F.01U.076.723 3.0 2009.03

Page 49
Image 49
Bosch Appliances UML-172-90, UML-202-90, UML-192-90 installation manual TroubleShooting Guide, Problem Solution