Bosch Appliances VG4-500I, VG4-200 Alarm I/O Setup, Alarm Setup Menu Choices, Inputs Setup, None

Models: VG4-500I VG4-200 VG4-300

1 76
Download 76 pages 38.12 Kb
Page 20
Image 20

16 en On-Screen Display Menu NavigationAutoDome Modular Camera System

2.7 Alarm I/O Setup

The Alarm Setup Menu provides access to the Alarm I/O Setup Menu to establish the alarm inputs and outputs and to configure alarm rules.

Alarm I/O Setup

Exit...

Inputs Setup...

Outputs Setup...

Rule Setup...

Restore Defaults...

Focus / Iris: Select

Alarm Setup Menu Choices:

 

Inputs Setup

 

Exit...

 

1.

Alarm Input 1

N.C.S.

2.

Alarm Input 2

N.O.S.

3.

Alarm Input 3

N.O.

4.

Alarm Input 4

N.C.

5.

Alarm Input 5

N.O.

6.

Alarm Input 6

N.C.

7.

Alarm Input 7

N.O.

8.

NONE

 

9.

NONE

 

10. NONE

11. NONE

12. NONE

Focus / Iris: Select Type

Right / Left: Select Mode

1-7 Physical Inputs

8-12 Command Inputs

Menu

Description

Sub-menu / Description

Default

 

 

 

Setting

 

 

 

 

Exit

Saves and exits the menu.

 

 

 

 

 

 

Inputs Setup

Defines physical inputs or events and

 

 

 

commands that can be used in a rule.

 

 

 

There are twelve (12) alarm inputs

 

 

 

available.

 

 

 

 

 

 

Inputs 1-7

Defines the type of physical input.

N.O.: Normally open dry contact.

N.O.

 

 

N.C.: Normally closed dry contact.

 

 

 

N.C.S.: Normally closed supervised contact.

 

 

 

N.O.S.: Normally open supervised contact.

 

 

 

 

 

Inputs 8-12

Defines input commands that can be

NONE: No command defined.

NONE

 

used in a rule. Command inputs can

Aux On: Programs a standard or custom key-

 

 

also be customized by using non-

board ON (1-99) command.

 

 

assigned keyboard command num-

Aux Off: Programs a standard or custom

 

 

bers.

keyboard OFF (1-99) command.

 

 

 

Shot: Programs a Preset shot or scene from

 

 

 

1-99. (200 Series 1-64).

 

 

 

AutoTrack: Triggers an alarm when set to

 

 

 

ON. (Available with 500i Series only).

 

 

 

Motion Detection: Triggers an alarm when

 

 

 

set to ON. (Available with 500i Series only).

 

 

 

 

 

NOTICE! Alarm inputs 1 and 2 provide tamper detection, if programmed as supervised, for

i breaks or shorts in an alarm circuit. See the AutoDome Modular Camera System Installation Manual for wiring instructions.

F01U064036 1.1 2007.01

VG4-200, VG4-300, VG4-500i Series User’s Manual

Bosch Security Systems, Inc.

Page 20
Image 20
Bosch Appliances VG4-500I, VG4-200, VG4-300 user manual Alarm I/O Setup, Alarm Setup Menu Choices, Inputs Setup, None