Bosch Power Tools FNH180K-16 manual Problem, REMEDy, Trouble Tool Operates PROPERLy Motor Runs

Models: FNH180K-16 FNH180-16BN

1 76
Download 76 pages 63.88 Kb
Page 17
Image 17

BM 2610034445 03-14_FNH180 3/27/14 11:52 AM Page 17

Trouble Shooting Guide (continued)

Many common problems can be solved easily by utilizing the chart below. For more serious or persistent problems, contact a Bosch service center or call 877-BOSCH-99.

!WARNING

PROBLEM

REMEDy

PROBLEM

Read instruction manual first! Remove battery pack and nails from the tool before making adjustments, assembling accessories or servicing.

TROUBLE: DRIVER BLADE STUCK DOWN (DOES NOT RETURN)

1.Jammed fastener

2.Damaged or worn return system

3.Debris in nosepiece

4.Damaged driver blade assembly

1.Remove battery pack from tool. Refer to “jam clearing” on page 12 for details.

2.Replace return system; see page 19 or see authorized service center

3.Clean nosepiece

4.Replace drive assembly; see page 21 or see authorized service center

TROUBLE: TOOL OPERATES, BUT DOES NOT DRIVE THE FASTENER FULLy

1.Battery pack not charged, or battery pack is damaged.

2.Depth adjustment set too shallow

3.Tool not firmly applied to workpiece

4.Material and fastener length too rigorous an application

5.Damaged or worn driver blade tip

6.Damaged or worn driver/return assembly

REMEDy 1. Charge or replace battery

2.Rotate depth adjustment wheel to a deeper setting

3.See instruction manual

4.Choose appropriate material or fastener length

5.Replace driver/return assembly; see page 21 or see authorized service center

6.Replace driver/return assembly; see page 21 or see authorized service center

TROUBLE: TOOL OPERATES PROPERLy (MOTOR RUNS AND

TOOL FIRES), BUT NO FASTENER DRIVEN

PROBLEM 1. No fasteners in magazine

2.Wrong size or angle fasteners

3.Debris in nosepiece

4.Debris in magazine

5.Worn magazine

6.Damaged or worn return system

7.Damaged or worn driver blade

8.Damaged follower spring

REMEDy 1. Load fasteners into magazine

2.Use only recommended fasteners

3.Clean nosepiece

4.Clean magazine

5.Replace magazine; see authorized service center

6.Replace return system; see page 19 or see authorized service center

7.Replace driver assembly; see page 21 or see authorized service center

8.Replace spring; see authorized service center

-17-

Page 17
Image 17
Bosch Power Tools FNH180K-16, FNH180-16BN manual REMEDy, Problem Trouble Driver Blade Stuck Down does not Return