When communicating via the parallel port (refer to Figure 14), the previously mentioned parameters are not considered. Refer to page 53 to configure the communication parameters for the printer. The values selected must be the same as those used by the host equipment connected to the printer.

For serial and parallel pinout and technical information, refer to the Appendix on page 93.

PrinterComputer

36-pin

male

PC

25-pin female

25-pin

male

10’ maximum

Cabling Requirements

Figure 14

Data cables must be fully shielded and fitted with metal or metalized connector shells. Shielded cables and connectors are required to prevent radiation and reception of electrical noise.

To minimize electrical noise pickup in the cable:

νKeep data cables as short as possible.

νDo not bundle the data cables tightly with the power cords.

νDo not tie the data cables to power wire conduits.

NOTES: Brady X-PLUSprinters comply with FCC “Rules and Regulations”, Part 15, for Class B Equipment, using fully shielded data cables. Use of unshielded cables may increase radiated emissions above the Class B limits.

RS-422 and RS-485 applications should use twisted shielded pairs as recommended in the Appendix of the TA/EA.-485 Specification.

22

Brady X-PLUSSeries User’s Guide