B. ELECTRONIC MACHINE CONTROLLER
Refer to page 11 for a full explanation of the Electronic Machine Controller functions.
C. FILTERS,GATE & EMERGENCY STOP DETAILS
The Filters, Gate and Emergency Stop devices are connected in a fail-safe
configuration. This means, these devices require a closed contact in normal working
condition. When the circuit goes open circuit, a fault condition results. The following
illustrations indicate the expected result.
Pressure Filter
When the Pressure
Filter is contaminated
and restricts the flow of
oil, the pressure build
up in the canister will
cause the indicator
contacts to open or an open circuit condition occurs from a broken cable or
terminal, the following is displayed. The trailer will continue to operate at a
reduced performance level.
Return Filter
When the Return Filter
is contaminated and
restricts the flow of oil,
the pressure build up in
the canister will cause
the indicator contacts to open or an open circuit condition occurs from a
broken cable or terminal, the following is displayed. The trailer will continue
to operate at a reduced performance level.
Cage Gates
When the Access
Doors are opened or
the Tilt Panels are not
tilted out, or the circuit
to the Access Door
sensor is damaged, the following is displayed. The trailer will NOT continue
to operate and the condition must be corrected.
Emergency Stop
When the Emergency
Stop is activated or the
circuit to the E/Stop is
damaged the following
will be displayed. The
trailer will NOT continue to operate and the condition must be corrected.
10
Green LED
Red LED
Green LED
Red LED
Green LED
Red LED
Green LED
Red LED