8
4.

Electronic Control Features and Operation

A. HAND-HELD WIRED REMOTE CONTROLLER
Load Dial
Controls the speed of the rotating arms from 0 rpm to maximum 40 rpm.
Load Drum button
Moves the drum to the rear of the machine so the cable can be loaded onto
the machine.
Stop button will stop the drum from moving and stop this function.
Pressing the Load Drum button while the function is active will have the same
effect as pressing the Stop button.
Transport Drum button
Moves the drum to the front of the machine for transport.
Stop button will stop the drum from moving and stop this function.
Pressing the Transport Drum button while the function is active will have the
same effect as pressing the Stop button.
Start / On button
Starts the machine so the Load Dial is functional and allows the arms
to rotate.
Stop button will stop the arms from rotating and stop this function.
Load Dial must be turned all the way to zero (counterclockwise) in order to acti-
vate the start button. LED will flash if the Load Dial is not all the way to zero.
4 digit 7 segment LED display
Normally displays the cable diameter in millimeters or the Drum Position.
Also displays error codes when an error condition is encountered: FL 1-FULL
if the pressure filter is full; FL 2-FULL if the return filter is full; or door-OPEn
when one of the safety gates is open. These error conditions will flash between
the first and second words and will display for 5-10 seconds before going
back to displaying the cable diameter or Drum Position. They will cycle on
approximately every 20-30 seconds.
An additional error code will be displayed when connected to the Condux FO
Blower and the blower has been stopped by the blower electronics: FOCB-
StOP. This error condition will flash between the first and second words and will
display as long as the trailer has been disabled by the blower. This condition
can be cleared by pressing the Stop button.