Bryant 315AAV instruction manual Multipoise Orientations, Fire, Injury Or Death Hazard

Models: 315AAV

1 60
Download 60 pages 15.94 Kb
Page 6
Image 6
Fig. 4 - Multipoise Orientations

315AAV

THE BLOWER IS LOCATED

TO THE RIGHT OF THE BURNER SECTION, AND AIR CONDITIONED AIR IS DISCHARGED TO THE LEFT.

THE BLOWER IS

LOCATED ABOVE THE BURNER SECTION, AND CONDITIONED AIR IS DISCHARGED DOWNWARD

THE BLOWER IS

LOCATED BELOW THE

BURNER SECTION, AND

CONDITIONED AIR IS

DISCHARGED UPWARD.

THE BLOWER IS

LOCATED TO THE LEFT

OF THE BURNER SECTION,

AND CONDITIONED AIR IS

DISCHARGED TO THE RIGHT.

A02097

Fig. 4 - Multipoise Orientations

This furnace must:

Sbe installed so the electrical components are protected from water.

Snot be installed directly on any combustible material other than wood flooring (refer to SAFETY CONSIDERATIONS).

Sbe located close to the chimney or vent and attached to an air distribution system. Refer to Air Ducts section.

Sbe provided ample space for servicing and cleaning. Always comply with minimum fire protection clear- ances shown on the furnace clearance to combustible construction label.

!WARNING

CARBON MONOXIDE POISONING / COMPONENT DAMAGE HAZARD

Failure to follow this warning could result in personal injury or death and unit component damage.

Corrosive or contaminated air may cause failure of parts containing flue gas, which could leak into the living space. Air for combustion must not be contaminated by halogen compounds, which include fluoride, chloride, bromide, and iodide. These elements can corrode heat exchangers and shorten furnace life. Air contaminants are found in aerosol sprays, detergents, bleaches, cleaning solvents, salts, air fresheners, and other household products. Do not install furnace in a corrosive or contaminated atmosphere. Make sure all combustion and circulating air requirements are met, in addition to all local codes and ordinances.

The following types of furnace installations may require OUTDOOR AIR for combustion due to chemical exposures:

SCommercial buildings

SBuildings with indoor pools S Laundry rooms

S Hobby or craft rooms, and S Chemical storage areas

If air is exposed to the following substances, it should not be used for combustion air, and outdoor air may be required for combustion:

SPermanent wave solutions

SChlorinated waxes and cleaners

SChlorine based swimming pool chemicals S Water softening chemicals

S De-icing salts or chemicals S Carbon tetrachloride

S Halogen type refrigerants

S Cleaning solvents (such as perchloroethylene) S Printing inks, paint removers, varnishes, etc. S Hydrochloric acid

S Cements and glues

S Antistatic fabric softeners for clothes dryers

SMasonry acid washing materials

All fuel-burning equipment must be supplied with air for fuel combustion. Sufficient air must be provided to avoid negative pressure in the equipment room or space. A positive seal must be made between the furnace cabinet and the return-air duct to prevent pulling air from the burner area and from draft safeguard opening.

!WARNING

FIRE, INJURY OR DEATH HAZARD

Failure to follow this warning could result in personal injury, death and/or property damage.

When the furnace is installed in a residential garage, the burners and ignition sources must be located at least 18 in. (457 mm) above the floor. The furnace must be located or protected to avoid damage by vehicles. When the furnace is installed in a public garage, airplane hangar, or other building having a hazardous atmosphere, the furnace must be installed in accordance with the NFPA 54/ANSI Z223.1-2009 . (See Fig. 5.)

6

Page 6
Image 6
Bryant 315AAV instruction manual Multipoise Orientations, Fire, Injury Or Death Hazard