Table 15 – Orifice Size and Manifold Pressure (In. W.C.) for Gas Input Rate

(Tabulated Data Based on 21,000 Btuh High-Heat/14,500 Btuh for Low-Heat Per Burner, Derated 4 Percent for Each 1000 Ft.

(305 M) Above Sea level)

 

 

 

AVG. GAS

 

 

 

SPECIFIC GRAVITY OF NATURAL GAS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ALTITUDE RANGE

HEAT VALUE

 

 

 

 

 

 

 

 

 

 

 

 

 

0.58

 

0.60

 

0.62

 

0.64

 

FT. (M)

(BTUH/CU

 

 

 

 

 

 

 

 

 

 

 

 

 

Orifice

 

Manifold

Orifice

 

Manifold

Orifice

 

Manifold

Orifice

 

Manifold

 

 

 

FT.)

 

Pressure

 

Pressure

 

Pressure

 

Pressure

 

 

 

No.

 

No.

 

No.

 

No.

 

 

 

 

 

 

High/Low

 

High/Low

 

High/Low

 

High/Low

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

900

42

 

3.2/1.5

42

 

3.3/1.6

42

 

3.4/1.6

42

 

3.5/1.7

 

 

 

925

43

 

3.7/1.8

43

 

3.8/1.8

42

 

3.2/1.5

42

 

3.3/1.6

 

 

0 to

950

43

 

3.5/1.7

43

 

3.6/1.7

43

 

3.7/1.8

43

 

3.8/1.8

 

 

975

43

 

3.3/1.6

43

 

3.4/1.6

43

 

3.5/1.7

43

 

3.7/1.7

USA

 

2000

 

 

 

 

 

 

 

 

 

 

 

 

 

1000

44

 

3.6/1.7

43

 

3.3/1.6

43

 

3.4/1.6

43

 

3.5/1.7

 

 

(0 to 610)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1025

44

 

3.4/1.6

44

 

3.6/1.7

43

 

3.2/1.5

43

 

3.3/1.6

 

 

 

1050

44

 

3.3/1.6

44

 

3.4/1.6

44

 

3.5/1.7

43

 

3.2/1.5

 

 

 

1075

45

 

3.8/1.8

44

 

3.2/1.5

44

 

3.3/1.6

44

 

3.4/1.6

 

 

 

1100

46

 

3.8/1.8

45

 

3.7/1.8

44

 

3.2/1.5

44

 

3.3/1.6

 

 

 

 

 

 

 

SPECIFIC GRAVITY OF NATURAL GAS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AVG. GAS

 

0.58

 

0.60

 

0.62

 

0.64

ALTITUDE RANGE

HEAT VALUE

Orifice

 

Manifold

Orifice

 

Manifold

Orifice

 

Manifold

Orifice

 

Manifold

 

FT. (M)

 

Pressure

 

Pressure

 

Pressure

 

Pressure

 

(BTUH/CU FT.)

No.

 

No.

 

No.

 

No.

 

 

 

 

 

High/Low

 

High/Low

 

High/Low

 

High/Low

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

800

43

 

3.8/1.8

42

 

3.2/1.5

42

 

3.3/1.6

42

 

3.4/1.6

 

 

 

825

43

 

3.5/1.7

43

 

3.7/1.7

43

 

3.8/1.8

42

 

3.2/1.5

 

 

2001 to

850

43

 

3.3/1.6

43

 

3.5/1.6

43

 

3.6/1.7

43

 

3.7/1.8

USA

 

875

43

 

3.2/1.5

43

 

3.3/1.6

43

 

3.4/1.6

43

 

3.5/1.7

 

3000 (610

900

44

 

3.4/1.6

44

 

3.5/1.7

43

 

3.2/1.5

43

 

3.3/1.6

 

 

to 914)

925

44

 

3.2/1.5

44

 

3.3/1.6

44

 

3.5/1.6

44

 

3.6/1.7

 

 

 

950

45

 

3.7/1.8

45

 

3.8/1.8

44

 

3.3/1.6

44

 

3.4/1.6

 

 

 

975

46

 

3.7/1.8

46

 

3.8/1.8

45

 

3.8/1.8

44

 

3.2/1.5

 

 

 

1000

46

 

3.5/1.7

46

 

3.6/1.7

46

 

3.8/1.8

45

 

3.7/1.8

 

 

 

 

 

 

 

SPECIFIC GRAVITY OF NATURAL GAS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AVG. GAS

 

0.58

 

0.60

 

0.62

 

0.64

ALTITUDE RANGE

HEAT VALUE

Orifice

 

Manifold

Orifice

 

Manifold

Orifice

 

Manifold

Orifice

 

Manifold

 

FT. (M)

 

Pressure

 

Pressure

 

Pressure

 

Pressure

 

(BTUH/CU FT.)

No.

 

No.

 

No.

 

No.

 

 

 

 

 

High/Low

 

High/Low

 

High/Low

 

High/Low

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

775

43

 

3.5/1.7

43

 

3.7/1.7

43

 

3.8/1.8

42

 

3.2/1.5

 

 

 

800

43

 

3.3/1.6

43

 

3.4/1.6

43

 

3.5/1.7

43

 

3.7/1.7

 

 

3001 to

825

44

 

3.6/1.7

43

 

3.2/1.5

43

 

3.3/1.6

43

 

3.4/1.6

 

 

850

44

 

3.4/1.6

44

 

3.5/1.7

44

 

3.6/1.7

43

 

3.2/1.5

USA

 

4000 (914

 

 

 

 

 

875

45

 

3.8/1.8

44

 

3.3/1.6

44

 

3.4/1.6

44

 

3.5/1.7

 

 

to 1219)

 

 

 

 

 

 

900

46

 

3.8/1.8

45

 

3.8/1.8

44

 

3.2/1.5

44

 

3.3/1.6

 

 

 

 

 

 

 

 

 

 

925

46

 

3.6/1.7

46

 

3.7/1.8

45

 

3.7/1.8

45

 

3.8/1.8

 

 

 

950

46

 

3.4/1.6

46

 

3.5/1.7

46

 

3.7/1.7

46

 

3.8/1.8

 

 

 

 

 

 

 

SPECIFIC GRAVITY OF NATURAL GAS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AVG. GAS

 

0.58

 

0.60

 

0.62

 

0.64

ALTITUDE RANGE

Orifice

 

Manifold

Orifice

 

Manifold

Orifice

 

Manifold

Orifice

 

Manifold

HEAT VALUE

 

 

 

 

 

FT. (M)

 

Pressure

 

Pressure

 

Pressure

 

Pressure

 

(BTUH/CU FT.)

No.

 

No.

 

No.

 

No.

 

 

 

 

 

High/Low

 

High/Low

 

High/Low

 

High/Low

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

750

43

3.3/1.6

43

3.4/1.6

43

3.5/1.7

43

3.6/1.7

 

 

4001 to

775

44

3.6/1.7

43

3.2/1.5

43

3.3/1.6

43

3.4/1.6

 

 

800

44

3.3/1.6

44

3.4/1.6

44

3.6/1.7

43

3.2/1.5

 

5000

 

 

 

 

 

 

 

 

 

USA

825

45

3.8/1.8

44

3.2/1.5

44

3.4/1.6

44

3.5/1.6

 

(1219 to

850

46

3.8/1.8

45

3.7/1.8

45

3.8/1.8

44

3.3/1.6

 

 

 

1524)

875

46

3.5/1.7

46

3.7/1.7

46

3.8/1.8

45

3.7/1.8

 

 

 

900

47

3.8/1.8

46

3.5/1.7

46

3.6/1.7

46

3.7/1.8

 

 

 

925

47

3.6/1.7

47

3.7/1.8

47

3.8/1.8

46

3.5/1.7

* Orifice numbers 43 are factory installed

44

Page 44