Bryant 345MAV ÐLeveling Legs, Ii.Installation On A Concrete Slab, Opening Dimensions In

Models: 345MAV

1 40
Download 40 pages 58.13 Kb
Page 15
Image 15
Fig. 14ÐLeveling Legs

516

516

1 34

1 34

516

516

1 34II.INSTALLATION ON A CONCRETE SLABOPENING DIMENSIONS (IN.)Fig. 15ÐFloor Opening in Concrete Slab 1 34Fig. 16ÐFurnace on a Concrete Slab

A89014

Fig. 14ÐLeveling Legs

3.Install another nut on other side of furnace base. (Install flat washer if desired.)

4.Adjust outside nut to provide desired height, and tighten inside nut to secure arrangement.

NOTE: Bottom closure must be used when leveling legs are used. See Bottom Closure Panel section.

II.INSTALLATION ON A CONCRETE SLAB

1.Construct hole in floor per dimensions in Fig. 15.

2.Place plenum and furnace as shown in Fig. 16.

III.INSTALLATION ON A COMBUSTIBLE FLOOR (DOWNFLOW APPLICATIONS)

1.Cut and frame hole in floor per dimensions in Installation Instructions packaged with downflow subbase kit.

NOTE: Remove furnace perforated, discharge duct flanges when they interfere with mating flanges on coil on downflow subbase. To remove furnace perforated, discharge duct flange, use wide duct pliers or duct flange tool to bend flange back-and-forth until it breaks off. Be careful of sharp edges. (See Fig. 17.)

WARNING: Do not bend duct flanges inward as shown in Fig. 17. This will affect airflow across heat exchangers and may cause limited cycling or premature heat ex- changer failure. Remove duct flange completely or bend it inward a minimum of 210° as shown in Fig. 17.

2.When complete, downflow subbase, plenum, and furnace (or coil casing when used) should be installed as shown in Fig. 18.

A

B

HOLE IN

FLOOR

 

 

 

 

A73382

OPENING DIMENSIONS (IN.)

 

 

 

 

 

 

FURNACE

A

B

 

CASING WIDTH

Heat Only

 

Heat/Cool*

 

 

 

 

 

 

 

17-1/2

16-7/16

19-5/8

 

19-7/16

21

19-7/8

19-5/8

 

19-7/16

24-1/2

23-7/16

19-5/8

 

19-7/16

 

 

 

 

 

*These dimensions apply when a model CD or CK Evaporator Coil casing is to be installed.

Fig. 15ÐFloor Opening in Concrete Slab

FURNACE

(Non-Garage Installation)PLENUM

A73383

Fig. 16ÐFurnace on a Concrete Slab

(Non-Garage Installation)