![Fig. 5ÐFactory-Shipped Upflow Tube Configuration](/images/new-backgrounds/54345/5434511x1.webp)
PLUG |
|
CAP |
|
COLLECTOR BOX |
|
DRAIN TUBE (BLUE |
|
& WHITE STRIPED) |
|
COLLECTOR BOX |
|
TUBE (PINK) |
|
COLLECTOR BOX |
|
TUBE (GREEN) |
|
INDUCER HOUSING |
|
(MOLDED) DRAIN |
|
TUBE (BEHIND |
|
COLLECTOR BOX |
|
DRAIN TUBE) |
|
COLLECTOR BOX |
|
DRAIN TUBE (BLUE) | CONDENSATE |
| |
| TRAP |
| |
| |
DRAIN TUBE |
|
COUPLING (LEFT |
|
DRAIN OPTION) |
|
PLUG
CAP
COLLECTOR BOX DRAIN TUBE (BLUE & WHITE STRIPED)
COLLECTOR BOX
TUBE (PINK)
COLLECTOR BOX
TUBE (GREEN)
COLLECTOR BOX DRAIN TUBE (BLUE)
CONDENSATE TRAP
INDUCER HOUSING DRAIN TUBE (VIOLET)
| |
| |
DRAIN TUBE |
|
DRAIN TUBE | |
ELBOWS (2) FOR | COUPLING (RIGHT |
LEFT DRAIN OPTION | DRAIN OPTION) |
A94163
Fig. 5ÐFactory-Shipped Upflow Tube Configuration
(Shown With Blower Access Panel Removed)
D.Condensate Trap Tubing (Alternate Upflow Orientation)
NOTE: See Fig. 6 or tube routing label on main furnace door to confirm location of these tubes.
1. Collector Box Drain Tube
Connect collector box drain tube (blue label) to condensate trap.
NOTE: On
2.Inducer Housing Drain Tube
a.Remove and discard LOWER (molded) inducer housing drain tube which was previously connected to conden- sate trap.
b.Use inducer housing drain extension tube (violet label and
c.Determine appropriate length, cut, and connect tube.
d.Clamp tube to prevent any condensate leakage.
3.Relief Port Tube
a.Connect relief port tube (green label) to condensate trap.
b.Use smaller diameter tube
Ð6Ð
A94164
Fig. 6ÐAlternate Upflow Tube Configuration and
Trap Location
c.Determine appropriate length, cut, and connect tube.
E. Condensate Trap Field Drain Attachment
Refer to Condensate Drain section for recommendations and procedures.
F. Pressure Switch Tubing
The LOWER collector box pressure tube (pink label) is factory connected to the pressure switch and should not require any modification.
NOTE: See Fig. 5 or 6 or tube routing label on main furnace door to check for proper connections.
G.Upper Collector Box and Inducer Housing (Unused) Drain Connections
UPPER COLLECTOR BOX DRAIN CONNECTION
Attached to the UPPER collector box drain connection is a
NOTE: See Fig. 5 or 6 or tube routing label on main furnace door to check for proper connections.
UPPER INDUCER HOUSING DRAIN CONNECTION
Attached to the UPPER (unused) inducer housing drain connection is a cap and clamp. This cap is used to prevent condensate leakage in this application. Ensure this connection is capped.