Bryant 345MAV ÐRoof Termination Preferred, ÐSidewall Termination with Straight Pipe, Ð30Ð

Models: 345MAV

1 40
Download 40 pages 58.13 Kb
Page 30
Image 30
Fig. 33ÐRoof Termination (Preferred)

ROOF

VENTFig. 35ÐSidewall Termination with Straight Pipe

MAINTAIN 12-IN. MINIMUM Ð30Ð

CLEARANCE ABOVE HIGHEST

ANTICIPATED SNOW LEVEL. MAXIMUM OF 24 IN. ABOVE ROOF.

A96191

Fig. 33ÐRoof Termination (Preferred)

OVERHANG OR ROOF

12MINIMUM

VENT Fig. 36ÐExample of Field Drain Attachment

Manual background90° Manual background

Manual backgroundManual backgroundManual backgroundMAINTAIN 12-IN.￿

CLEARANCE

ABOVE HIGHEST

ANTICIPATED SNOW

LEVEL OR GRADE,

WHICHEVER IS

GREATER.

A96192

Fig. 34ÐSidewall Termination with 2 Elbows (Preferred)

OVERHANG OR ROOF

12MINIMUM

VENT

6-IN. MINIMUM CLEARANCE BETWEEN WALL AND END OF VENT PIPE.

10-IN. MAXIMUM PIPE LENGTH

Manual backgroundManual backgroundManual backgroundMAINTAIN 12-IN.￿

CLEARANCE

ABOVE HIGHEST

ANTICIPATED SNOW

LEVEL OR GRADE,

WHICHEVER IS

GREATER.

A96210

Fig. 35ÐSidewall Termination with Straight Pipe

Ð30Ð

32°F MINIMUM INSTALLED AMBIENT OR FREEZE PROTECTION REQUIRED

A93058

CAUTION: Unit must not be installed, operated, and then turned off and left in an unoccupied structure during cold weather when temperature drops to 32°F and below unless drain trap and drain line have adequate freeze protection. See Service and Maintenance Instructions for winterizing procedure.

OPEN STAND

PIPE FOR

A/C OR

HUMIDIFIER

DRAIN

TEE

TO OPEN

DRAIN

A94054

Fig. 36ÐExample of Field Drain Attachment

Page 30
Image 30
Bryant 345MAV ÐRoof Termination Preferred, ÐSidewall Termination with Straight Pipe, ÐExample of Field Drain Attachment