167
TYPICAL WIRING SCHEMATICS — 581C

LEGEND

OFM Outdoor(Cond enser) Fan Motor
OLR Overload Relay
P—Plug
PL PlugAssembly
QT QuadrupleTerminal
RS RolloutSwitch
SAT Supply Air Temperature Sensor
TRAN — Transformer
FieldSplice
MarkedWire
Terminal(Marked)
Terminal(Unmarked)
TerminalBlock
C
Contactor,Compressor
C
AP Capacitor
C
LO Compressor Lockout
C
OMP — Compressor Motor
E
QUIP — Equipment
F
PT FreezeUp Protection Ther mostat
F
U—Fuse
G
ND Ground
H
PS High-Pressure Switch
H
S—Hall-EffectSensor
I
Ignitor
I
DM Induced-Draft Motor
I
FC Indoor Fan Contactor
I
FM Indoor Fan Motor
I
GC Integrated Gas Unit Controller
L
PS Low-PressureSwitch
L
S—LimitSwitch
MGV MainGas Valve
Splice
Splice(Marked)
FactoryWiring
FieldContro l Wiring
FieldPower Wiring
Accessoryor OptionalWiri ng
Toindicate common potential only
;
notto represent wiring.
NOTES:
1. If any of the original wire furnishedmust be r eplaced, it mus
t
bereplaced wit h type 90 C wire or its equivalent.
2. Three phase motors are protected under primary single
phasingconditions.
3. Use copper conductors only.
4. TRAN is wired for 230 v unit. If unit is to be run with 208 v
powersuppl y,disconnect BLK wire f rom 230v tap (ORN
)
andconnect to 2 08 v tap (RED). Insulate end of 230 v tap.