Bunn 34766.0000S Programming The Dispenser, Menu Screen, Action, Description, Tank Temp, 351 +

Models: 34766.0000S

1 34
Download 34 pages 23.55 Kb
Page 13
Image 13
PROGRAMMING THE DISPENSER

PROGRAMMING THE DISPENSER

Remove the lower splash guard assembly to access the digital programming module with LCD display. Press the Down Arrow key to inter the programming menu.

Use the Up and Down Arrow keys to scroll through the menu screens.

Select Exit to leave the programming function and return to normal operations. NOTE 1: Flashing menu items indicate which selection is active.

NOTE 2: Values shown below are the factory default values for English units.

NOTE 3: Values in [X - X] are the Min. and Max. for that function.

 

MENU SCREEN

ACTION

DESCRIPTION

 

 

 

 

 

 

TANK TEMP XXX

 

Use the Down Arrow Key to enter

Normal Display for LCA models, (No Chiller)

 

AMBIENT UNIT

 

Programming Functions

 

 

 

 

 

 

 

 

 

 

 

 

 

TANK TEMP XXX

 

Use the Down Arrow Key to enter

Normal Display for LCC models, (with Chiller)

 

 

 

CABINET TEMP XX

Programming Functions

 

 

 

 

 

 

 

 

 

 

L DISPENSE RATIO

 

Use the (+) or (-) buttons to

Enter the desired Mix Ratio for the concentrate

(-) 35:1 (+)

 

 

adjust the Mix Ratio

used in the Left dispenser. [20:1 - 100:1]

 

 

 

 

 

 

 

 

 

 

SET LF TUBE SIZE

 

Select tube size.

Enter Pump Tube Size to be used in the Left

1/8

EXIT 3/16

 

 

metering pump, (see Tube Selection Chart)

 

 

 

 

 

 

 

 

 

 

R DISPENSE RATIO

 

Use the (+) or (-) buttons to

Enter the desired Mix Ratio for the concentrate

(-) 35:1 (+)

 

 

adjust the Mix Ratio

used in the Right dispenser. [20:1 - 100:1]

 

 

 

 

 

 

 

 

 

 

SET RT TUBE SIZE

 

Select tube size.

Enter Pump Tube Size to be used in the Right

1/8

EXIT 3/16

 

 

metering pump, (see Tube Selection Chart)

 

 

 

 

 

 

 

 

 

 

FLAVOR GUARD ?

 

Select (YES) to activate. Select

Select Yes, if you are ready to calibrate the Flavor

 

NO

EXIT YES

 

(NO) to deactivate.

Guard sensor. Select NO, if you do not wish to

 

 

 

 

 

 

use this feature, (see Flavor Guard)

 

 

 

 

 

 

If NO - go to LF DISP VOLUME menu.

LF TASTE OK ? NO EXIT YES

FIND LF TARGET PULL DISPENSE

RT TASTE OK ? NO EXIT YES

 FIND RT TARGET PULL DISPENSE

Select (YES) or (NO)

Select YES, if you have dispensed several cups

 

and are satisfied with the Left dispenser flavor.

 

Select NO, if you have not run taste test.

Place a 16 Oz. (500 mL) cup

Calibrates the Left FlavorGard™ sensor to the

under the Left dispense tip, then

current MixProfile. The dispenser will shut OFF

activate the Left dispenser

automatically when finished.

Select (YES) or (NO)

Select YES, if you have dispensed several cups

 

and are satisfied with the Right dispenser flavor.

 

Select NO, if you have not run taste test.

Place a 16 Oz. (500 mL) cup

Calibrates the Right FlavorGard™ sensor to the

under the Right dispense

current MixProfile. The dispenser will shut OFF

tip, then activate the Right

automatically when finished.

dispenser

 

13

34766 042304

 

Page 13
Image 13