Bunn 34766.0000S Troubleshooting Continued Dispenser Diagnostics-LCD Display, Possible Cause

Models: 34766.0000S

1 34
Download 34 pages 23.55 Kb
Page 27
Image 27
Troubleshooting (Continued)

Troubleshooting (Continued)

Dispenser Diagnostics-LCD Display

Screen Displayed

 

Possible Cause

Troubleshooting Procedures

 

 

 

 

 

 

LF TARGET RPM

1.

The Tube Size selected for the Left

Refer to “Selecting the Correct Pump

TOO HIGH !!

 

Hand Dispenser is too small for the

Tubing” section of the manual.

 

 

 

 

application.

 

 

 

 

 

 

 

 

 

 

 

 

TUBE TOO SMALL

2.

The Ratio selected for the Left Hand

Refer to recommended Dispense Ratio

CHECK DISP RATIO

 

Dispenser is not correct for the

on the product label.

 

 

 

 

application.

 

 

 

 

 

 

 

RT TARGET RPM

1.

The Tube Size selected for the Right

Refer to “Selecting the Correct Pump

TOO HIGH !!

 

Hand Dispenser is too small for the

Tubing” section of the manual.

 

 

 

 

application.

 

 

 

 

 

 

 

 

 

 

 

 

TUBE TOO SMALL

2.

The Ratio selected for the Right

Refer to recommended Dispense Ratio

CHECK DISP RATIO

 

Hand Dispenser is not correct for the

on the product label.

 

 

 

 

application.

 

 

 

 

 

 

 

LF TARGET RPM

1.

The Tube Size selected for the Left

Refer to “Selecting the Correct Pump

TOO LOW !!

 

Hand Dispenser is too large for the

Tubing” section of the manual.

 

 

 

 

application.

 

 

 

 

 

 

 

 

 

 

 

 

TUBE TOO LARGE

2.

The Ratio selected for the Left Hand

Refer to recommended Dispense Ratio

CHECK DISP RATIO

 

Dispenser is not correct for the

on the product label.

 

 

 

 

application.

 

 

 

 

 

 

 

RT TARGET RPM

1.

The Tube Size selected for the Right

Refer to “Selecting the Correct Pump

TOO LOW !!

 

Hand Dispenser is too large for the

Tubing” section of the manual.

 

 

 

 

application.

 

 

 

 

 

 

 

 

 

 

 

 

TUBE TOO LARGE

2.

The Ratio selected for the Right

Refer to recommended Dispense Ratio

CHECK DISP RATIO

 

Hand Dispenser is not correct for the

on the product label.

 

 

 

 

application.

 

 

 

 

 

 

 

LEFT BIB EMPTY!

1.

Concentrate BIB is Empty.

Replace BIB, see loading the Concentrate

 

 

 

2.

BIB Not properly connected.

Check BIB Connector Fittings

REPLACE PRODUCT

3.

Tubing kinked or blocked.

Check Tubing installation

CHECK THRESHOLD

4.

Empty BIB Warning set too high.

Check Threshold, see Field Calibrating

 

 

 

 

 

the Empty BIB Warning

 

 

 

 

 

 

RIGHT BIB EMPTY!

1.

Concentrate BIB is Empty.

Replace BIB, see loading the Concentrate

 

 

 

2.

BIB Not properly connected.

Check BIB Connector Fittings

REPLACE PRODUCT

3.

Tubing kinked or blocked.

Check Tubing installation

CHECK THRESHOLD

4.

Empty BIB Warning set too high.

Check Threshold, see Field Calibrating

 

 

 

 

 

the Empty BIB Warning

 

 

 

 

 

 

27

34766 011604

 

Page 27
Image 27
Bunn 34766.0000S manual Troubleshooting Continued Dispenser Diagnostics-LCD Display, Possible Cause, the Empty BIB Warning