CAL RIGHT PUMP ?

MENU SCREEN

ACTION

DESCRIPTION

If NO - skip to next menu.

CAL RIGHT PUMP ?

PULL DISPENSER

CAL RT PUMP VOL (-) 43mL (+)

CAL RT WTR FLOW

PULL DISPENSER

CAL RT WTR VOL (-) 36.0OZ (+)

CAL RIGHT SIDE ? EXIT YES

Place a 50 mL (#34843.1000) graduated cylinder under the Right dispense tip, then activate the Right Dispenser

Use the (+) or (-) buttons to enter volume collected

Place a 64 Oz. (2000 mL) container under the Right dispense tip, then activate the Right Dispenser

Use the (+) or (-) buttons to enter volume collected

NONE

The Right Pump will dispense concentrate for 20 seconds, then shut off automatically. Collect and measure the concentrate dispensed.

Enter the volume of concentrate measured from the Right Pump in mL(not Oz.) regardless of Preferred Units selected.

The Right Dispenser will dispense hot water for 20 seconds, then shut off automatically. Collect and measure the water dispensed.

Enter the volume of the water measured from the Right dispenser in Oz. (mL)

Scroll down to bypass this screen.

CAL RT WTR FLOW For Portion Control Dispensers (LCA-2 PC, LCA-2C PC, LCA-2A PC) only

CAL HOT WTR FLO ?

PULL DISPENSE

CAL HOT WTR VOL (-) 34.0OZ (+)

XXXCAL -> XXX (-) TankTemp (+)

FlvrGrdRange 10%

(-) EXIT (+)

LfFlvrGrdTargets

RPM XXX-CON XXX

RtFlvrGrdTargets

RPM XXX-CON XXX

Place a 64 Oz. (2000 mL) container under the Hot Water dispense tip, then activate the Hot Water Dispenser

Use the (+) or (-) buttons to enter volume collected

Use the (+) or (-) buttons to adjust temperature reading

Use the (+) or (-) buttons to adjust % value

NONE

NONE

The Hot Water Dispenser will dispense for 20 seconds, then shut off automatically. Collect and measure the water dispensed.

Enter the volume of the water measured from the Hot Water Dispenser in Oz. (mL)

Adjust the display reading to match a calibrated probe inserted next to the Tank Sensor, °F (°C).

Used to set the maximum adjustment the Flavor Guard feature is allowed to make, [3 - 15%].

Displays the Left Dispenser target RPM and Conductance Reading, (Diagnostics Only)

Displays the Right Dispenser target RPM and Conductance Reading, (Diagnostics Only)