Troubleshooting (Continued)
Screen Displayed |
| Possible Cause |
| Troubleshooting Procedures | ||||
|
|
|
|
|
|
|
| |
OVERFLOW CUP | 1. | Refill valve stuck open |
| Service Required | ||||
FULL. EMPTY CUP | 2. | Faulty refill probe |
| Service Required | ||||
|
|
|
|
|
| |||
|
|
|
|
| 3. | Faulty overflow switch |
| Service Required |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| |
HEATING TIME TOO | 1. | Tank Heater failure |
| Service Required | ||||
LONG | 2. | Triac failure |
| Service Required | ||||
|
|
|
|
|
| |||
CHECK HEATING |
|
|
|
| ||||
CIRCUIT | 3. | Tank Temp. sensor failure |
| Service Required | ||||
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| |
FILL TIME TOO LONG | 1. | Water shut off to dispenser |
| Check water supply | ||||
|
|
|
|
|
|
| ||
|
|
|
|
|
|
| ||
CHECK WATER SUPPLY | 2. | Inlet Solenoid Valve failure |
| Service Required | ||||
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| |
TANK TEMP SENSOR | 1. | Corresponding Temperature | Sensor | Service Required | ||||
OUT OF RANGE |
| Probe wire(s) broken or disconnected |
| |||||
CHECK |
|
|
|
|
|
|
| |
| FOR BAD |
|
|
|
| |||
CONNECTIONS |
|
|
|
| ||||
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| ||
COOL TEMP SENSOR | 1. | Corresponding Temperature | Sensor | Service Required | ||||
OUT OF RANGE |
| Probe wire(s) broken or disconnected. |
| |||||
CHECK |
|
| 2. | Product cabinet temperature too low. | Service Required | |||
| FOR BAD | |||||||
CONNECTIONS |
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
EVAP TEMP SENSOR | 1. | Corresponding Temperature | Sensor | Service Required | ||||
OUT OF RANGE |
| Probe wire(s) broken or disconnected. |
| |||||
CHECK |
|
|
|
|
|
|
| |
FOR BAD | 2. | Evaporator temperature too low. | Service Required | |||||
CONNECTIONS |
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
TANK TEMP SENSOR | 1. | Corresponding Temperature | Sensor | Service Required | ||||
OUT OF RANGE |
| Probe wire(s) shorted to housing, or to |
| |||||
|
|
|
|
|
| each other. |
|
|
CHECK WIRE FOR |
|
|
|
| ||||
SHORTS |
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
COOL TEMP SENSOR | 1. | Corresponding Temperature | Sensor | Service Required | ||||
OUT OF RANGE |
| Probe wire(s) shorted to housing, or |
| |||||
|
|
|
|
|
| to each other. |
|
|
CHECK | WIRE FOR |
|
|
|
| |||
SHORTS | 2. | Product cabinet temperature too high. | Service Required | |||||
|
|
|
|
|
|
|
|
|
28 | 34766 011604 |
|