Bunn 34766.0000S manual Screen Displayed, Troubleshooting Continued, Possible Cause

Models: 34766.0000S

1 34
Download 34 pages 23.55 Kb
Page 28
Image 28
Screen Displayed

Troubleshooting (Continued)

Screen Displayed

 

Possible Cause

 

Troubleshooting Procedures

 

 

 

 

 

 

 

 

OVERFLOW CUP

1.

Refill valve stuck open

 

Service Required

FULL. EMPTY CUP

2.

Faulty refill probe

 

Service Required

 

 

 

 

 

 

 

 

 

 

 

3.

Faulty overflow switch

 

Service Required

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HEATING TIME TOO

1.

Tank Heater failure

 

Service Required

LONG

2.

Triac failure

 

Service Required

 

 

 

 

 

 

CHECK HEATING

 

 

 

 

CIRCUIT

3.

Tank Temp. sensor failure

 

Service Required

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FILL TIME TOO LONG

1.

Water shut off to dispenser

 

Check water supply shut-off

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CHECK WATER SUPPLY

2.

Inlet Solenoid Valve failure

 

Service Required

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TANK TEMP SENSOR

1.

Corresponding Temperature

Sensor

Service Required

OUT OF RANGE

 

Probe wire(s) broken or disconnected

 

CHECK

 

 

 

 

 

 

 

 

FOR BAD

 

 

 

 

CONNECTIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COOL TEMP SENSOR

1.

Corresponding Temperature

Sensor

Service Required

OUT OF RANGE

 

Probe wire(s) broken or disconnected.

 

CHECK

 

 

2.

Product cabinet temperature too low.

Service Required

 

FOR BAD

CONNECTIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EVAP TEMP SENSOR

1.

Corresponding Temperature

Sensor

Service Required

OUT OF RANGE

 

Probe wire(s) broken or disconnected.

 

CHECK

 

 

 

 

 

 

 

FOR BAD

2.

Evaporator temperature too low.

Service Required

CONNECTIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

TANK TEMP SENSOR

1.

Corresponding Temperature

Sensor

Service Required

OUT OF RANGE

 

Probe wire(s) shorted to housing, or to

 

 

 

 

 

 

 

each other.

 

 

CHECK WIRE FOR

 

 

 

 

SHORTS

 

 

 

 

 

 

 

 

 

 

 

 

 

COOL TEMP SENSOR

1.

Corresponding Temperature

Sensor

Service Required

OUT OF RANGE

 

Probe wire(s) shorted to housing, or

 

 

 

 

 

 

 

to each other.

 

 

CHECK

WIRE FOR

 

 

 

 

SHORTS

2.

Product cabinet temperature too high.

Service Required

 

 

 

 

 

 

 

 

 