Appendix

Appendix

Troubleshooting Procedures

If Grill Fails to Operate Properly:

1.Turn off gas at source, turn the Control Knobs to the ‘OFF’ position and wait five minutes before try- ing again.

2.Check gas supply at a connections.

3.Repeat lighting procedure and if grill still fails to operate properly, turn off gas at source, turn the con- trol knobs to the off position and wait for the grill to cool down and check the following:

Cannot Ignite

1.If the burner does not turn on, use the following procedure with Figure 51.

Check for proper position of sparker tip should be pointing forward towards the front of the brass burner.

Make sure there is a blue spark at the electrode tip to the brass burner.

Make sure ignitor wire is connected firmly to the valve ignition device and electrode.

Make sure valve orifice is free of any debris, dust or grease.

Make sure valve orifice is aligned inside the front hole of the brass burner.

2.If there is no spark at all, replace th electrode or ignitor wire.

Note: Turn off the gas at the source while troubleshooting.

 

Figure 51

 

Problem:

Misalignment of burner tube(s) over orifice(s)

 

Solution:

Reposition the burner tube to properly seat over orifice.

 

Problem:

Obstruction In Gas Line

 

Solution:

Remove fuel line from grill. Do not smoke or perform any maintenance in the vicinity of

 

an open flame. Open gas valve for one second to blow out any debris. Close off gas valve

 

and reconnect fuel line securely.

 

Problem:

Plugged Orifice

 

Solution:

Remove cooking grills, Flame Tamer and grease tray. Remove burners from bottom of fire-

 

box by pulling cotter pin from beneath burner peg using a standard screwdriver or needle

 

 

Barbecue Owner’s Manual