INITIAL SET-UP

INITIAL SET-UP

1.Locate the drip tray assembly beneath the dispenser nested in the packing material.

2.Remove the drip tray and the drip tray cover and set them aside.

3.Remove the water strainer assembly from the drip tray and set it aside.

4.Remove the four legs from the drip tray, apply non-skid pads to the bottom of the legs and securely install the legs in the dispenser base.

ELECTRICAL REQUIREMENTS

CAUTION - The dispenser must be disconnected from the power source until specified in Initial Set-Up.

The 120 volt version of this dispenser has an attached cordset. The mating connector must be a NEMA 5-15R.

L2 RED

WHITE

 

NEUTRAL

WHITE

120V. A.C.

L1BLACK

 

 

L1BLACK

 

L2 WHITE

 

120V A.C.

 

 

208 or

 

240V A.C.

240V a.c.

L1 BLACK

120V A.C.

 

 

 

P2185

P1841

P2185

 

 

Requires 2-wire grounded ser-

Requires 3-wire, grounded service

“A” models require 2-wire,

vice rated 120 volts ac, 15 amp,

rated 120/208 volts or 120/240 volts

grounded service rated 240

single phase, 60 Hz

ac, 20 amp, single phase, 60 HZ

volts ac, 20 amp, single

 

 

phase, 50 Hz

ELECTRICAL HOOK-UP

CAUTION - Improper electrical installation will damage electronic components.

1.An electrician must provide electrical service as specified.

2.Using a voltmeter, check the voltage and color coding of each conductor at the electrical source.

3.Open the front door of the dispenser and place the heater switch in the “OFF” (upper position).

4.Remove the right side panel of the dispenser.

120 volt versions proceed to step 6.

120/240 volt and 240 volt versions proceed to next step.

5.Install the electrical wiring to the terminal block as illustrated above.

6.Connect the dispenser to the power source and verify the voltage at the terminal block. Reinstall the side panel.

7.If plumbing is to be hooked-up later be sure the dispenser is disconnected from the power source. If plumbing has been hooked-up, the dispenser is ready for Initial Fill & Heat.

PLUMBING REQUIREMENTS

This dispenser must be connected to a COLD WATER system with operating pressure between 20 and 90 psi (138 and 620 kPa) from a 12" or larger supply line. A shut-off valve should be installed in the line before the dispenser. Install a regulator in the line when pressure is greater than 90 psi (620 kPa) to reduce it to 50 psi (345 kPa). The water inlet fitting is 14" flare.

NOTE - Bunn-O-Matic recommends 14" copper tubing for installations of less than 25 feet and 38" for more than 25 feet from the 12" water supply line. At least 18 inches of an FDA approved flexible beverage tubing, such as reinforced braided polyethylene or silicone, before the dispenser will facilitate movement to clean the countertop. It can be purchased direct from Bunn-O-Matic (part number 00326-0000). Bunn-O-Matic does not recommend the use of a saddle valve to install the dispenser. The size and shape of the hole made in the supply line by this type of device may restrict water flow.

This equipment must be installed to comply with the Basic Plumbing Code of the Building Officials and Code Administrators International, Inc. (BOCA) and the Food Service Sanita- tion Manual of the Food and Drug Administration (FDA).