DRAINING THE HOT WATER TANK

CAUTION - The dispenser must be disconnected from the power source throughout these steps.

1.Disconnect the dispenser from the power source.

2.Open front door and place tank heater switch in the “OFF” (upper) position.

3.Shut-off and disconnect the incoming water supply.

4.Remove the top panel.

5.Gently remove one of the grommets from the tank lid.

6.Insert a tube to the bottom of the tank and syphon ALL of the water out. (Bunn-O-Matic has a syphon assembly #12440.0000 available for this purpose.)

NOTE - The dispenser must be refilled using the INITIAL FILL & HEAT steps before reconnecting to the power source.

HOPPER DISPENSE RATE OF PRODUCT

1.Hopper dispense rate with 22 tooth gear and auger wire is approximately 4 to 6 grams per second.

2.Hopper dispense rate with 22 tooth gear and auger wire with optional restrictor is approximately 3 to 5 grams per second.

3.Hopper dispense rate with optional 32 tooth gear and auger wire is 6 to 9 grams per second.

TROUBLESHOOTING

A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic Technical Service Department.

Inspection, testing, and repair of electrical equipment should be performed only by qualified service personnel.

All electronic components have 120 volt ac or 240 volt ac and low voltage dc potential on their terminals. Shorting of terminals or the application of external voltages may result in board failure.

Intermittent operation of electronic circuit boards is unlikely. Board failure will normally be permanent. If an intermittent condition is encountered, the cause will likely be a switch contact or a loose connection at a terminal or crimp.

Solenoid removal requires interrupting the water supply to the valve. Damage may result if solenoids are energized for more than ten minutes without a supply of water.

The use of two wrenches is recommended whenever plumbing fittings are tightened or loosened. This will help to avoid twists and kinks in the tubing.

Make certain that all plumbing connections are sealed and electrical connections tight and isolated.

This unit is heated at all times. Keep away from combustibles.

WARNING – • Exercise extreme caution when servicing electrical equipment.

Unplug the dispenser when servicing, except when electrical tests are specified.

Follow recommended service procedures

Replace all protective shields or safety notices

6