Grinder Scale (Model G9WD only)

SERVICE (Cont.)

Grinder Scale (Model G9WD only)

CALIBRATION

1.Place empty funnel into funnel rails.

2.Press and hold the right hidden (copyright) button until the “MACHINE TYPE” menu appears. (See level 2 programming)

3.Press the middle button under the screen until the “CALIBRATE SCALES?” menu appears.

4.Press the right button under “YES” in the “CALIBRATE SCALES?” screen.

5.Press the middle button under “TARE”.

6.When the “PLACE 8oz” screen appears, remove the funnel, and place a calibrated 8oz weight in the funnel. Replace the funnel in the funnel rails.

7.Press the middle button under “DONE”. The grinder will go through a calibration, and then return to the main screen when calibration is complete.

8.Remove the weight from the funnel. The grinder is now ready calibrated and ready for normal operation.

LEVEL 2 FUNCTIONS:

Press the hidden

(copyright) button for 3 seconds in “ENTER PASSWORD” menu.

MACHINE TYPE

WEIGHT TIMED

CALIBRATE SCALE ?

NO YES

MODIFY MAXBIT

NO SPREAD? YES

SHUToff Bits ##

(-) DONE (+)

MaxBits read #

(-) DONE (+)

Finished, returns

to main screen

CALIBRATION OZ

(-) 8.00 (+)

CALIBRATE SCALES EXIT TARE

PLEASE WAIT TARE

PLACE 8.00 oz

EXIT DONE

PLEASE WAIT CAL