Bunn G9-2T DBC, LPG-2, G9WD, G2 TRIFECTA service manual EMI Filter Models FPG & FPG-2, SERVICE Cont

Models: FPG-2 G9-2T DBC G9-2 G2 TRIFECTA G9 G9WD LPG-2

1 79
Download 79 pages 39.46 Kb
Page 54
Image 54
EMI Filter (Models FPG & FPG-2)

SERVICE (Cont.)

EMI Filter (Models FPG & FPG-2)

FIG 60 EMI FILTER

Location:

The EMI Filter is located inside the rear cover of the grinder housing.

Test Procedure:

1.Disconnect the dispenser from the power source.

2.Disconnect the two red wires and two white wires on the EMI Filter from the EMI Filter wiring harness.

3.Check for resistance between the two red leads on the EMI Filter. (Fig 61)

If resistance is present as described the EMI Filter is operating properly.

If resistance is not present as described, replace the EMI Filter.

Removal and Replacement:

1.Disconnect the wires from the EMI Filter.

2.Remove the two screws securing the EMI Filter.

3.Remove and discard EMI Filter.

4.Install new EMI Filter using two screws to secure EMI Filter to its former location.

5.Refer to schematic when reconnecting the wires.

118.0 kΩ - 118.5 kΩ

Across either pair

FIG 61 EMI FILTER TERMINALS