Bunn G2 TRIFECTA, G9WD, G9-2 Circuit Breaker Models LPG, LPG-2E,FPG, FPG-2DBC, SERVICE Cont

Models: FPG-2 G9-2T DBC G9-2 G2 TRIFECTA G9 G9WD LPG-2

1 79
Download 79 pages 39.46 Kb
Page 31
Image 31
Circuit Breaker (Models LPG, LPG-2E, FPG, FPG-2 DBC)

SERVICE (Cont.)

Circuit Breaker (Models LPG, LPG-2E, FPG, FPG-2 DBC)

FIG. 22 CIRCUIT BREAKER

P1036

 

Location:

The circuit breaker is located on the rear of the grinder next to the power cord strain relief bushing. The circuit breaker is not available on Model LPG equipped with capacitor.

Test Procedure:

1.Disconnect grinder from the power source.

2.Remove the wires from the circuit breaker.

3.Check for continuity between the terminals. Conti- nuity must be present between the terminals.

If continuity is present as described the circuit breaker is functioning properly.

If continuity is not present as described, press reset button and repeat step #3, if continuity is not present as described, replace the circuit breaker.

Removal and Replacement:

1.Remove the wires from the circuit breaker.

2.Remove the face nut securing circuit breaker to the motor support.

3.Remove circuit breaker.

4.Install new circuit breaker in motor support and secure with face nut.

5.Reconnect the wires.

6.Refer to FIG. 23 when reconnecting the wires.

RED from Motor-LPG-2E

BLK from Start Switch-LPG

Manual background BLK from Power Cord

FIG. 23 CIRCUIT BREAKER TERMINALS P1037

31

41545 122209

 

Page 31
Image 31
Bunn G2 TRIFECTA, G9WD, G9-2T DBC service manual Circuit Breaker Models LPG, LPG-2E,FPG, FPG-2DBC, SERVICE Cont