Bunn LPG-2, G9WD, G2 TRIFECTA, FPG-2 Timer Model G9-2, Digital Timer, Analog Timer, SERVICE Cont

Models: FPG-2 G9-2T DBC G9-2 G2 TRIFECTA G9 G9WD LPG-2

1 79
Download 79 pages 39.46 Kb
Page 49
Image 49
Timer (Model G9-2)

SERVICE (Cont.)

Timer (Model G9-2)

+

VOLTAGE

WARNING

HAZARDOUS

Digital Timer

E TIME

DISPENS

VOLTAGE

WARNING

ARDOUS

HAZ

Analog Timer

P613

FIG 52 TIMER

Location:

The timer is located in the grinder base.

Test Procedure:

1.Unplug the grinder.

2.Connect a voltmeter across contacts 1 & 2 of the larger connector (P4) on the timer board. Plug-in the grinder. The indication must be 120 volts ac for 120V models and 230 volts ac for 230V models.

3.Unplug the grinder.

4.Connect a voltmeter across contacts 2 & 6 of the larger connector (P4) on the timer board. Plug-in the grinder. When the control switch is in any posi- tion except “OFF” (center), the indication must be 120 volts ac for 120V models and 230 volts ac for 230V models.

5.Unplug the grinder.

If voltage is present as described, proceed to #6.

If voltage is not present as described, refer to the Wiring Diagram and check the grinder wiring harness.

6.Connect a voltmeter across contacts 3 & 7 of the larger connector (P4) on the timer board. Plug-in the grinder. Momentarily press the Off/On/Start switch to “START” (lower) position and release. The indication must be 120 volts ac for 120V models and 230 volts ac for 230V models.

7.Unplug the grinder.

If voltage is present as described, proceed to #8.

If voltage is not present as described, replace the timer.

8.Connect a voltmeter across contacts 4 & 7 of the larger connector (P4) on the timer board. Plug-in the grinder. Place the hopper selector switch to the left position. Momentarily press the Off/On/ Start switch to the “START” (lower) position and release. The indication must be 120 volts ac for 120V models and 230 volts ac for 230V models and should remain for the approximate timer setting.

9.Unplug the grinder.

If voltage is present as described, proceed to #10.

If voltage is not present as described, replace the timer.

10.Connect a voltmeter across contacts 5 & 7 of the larger connector (P4) on the timer board. Plug-in the grinder. Place the hopper selector switch to the right position. Momentarily press the Off/On/ Start switch to the “START” (lower) position and release. The indication must be 120 volts ac for 120V models and 230 volts ac for 230V models and should remain for the approximate timer setting.

11.Unplug the grinder.

If voltage is present as described, the timer is operat- ing properly.

If voltage is not present as described, replace the timer.

Removal and Replacement:

1.Separate the grinder wiring harness connectors from the timer circuit board.

2.Remove the relay from the timer bracket.

3.Attach the relay to the new timer bracket.

4.Refer to the following illustration when reattaching the connectors.

5.Refer to the Adjustments section to reset the vol- ume dispensed.

49

41545 122209

 

Page 49
Image 49
Bunn LPG-2, G9WD, G2 TRIFECTA, G9-2T DBC, FPG-2 service manual Timer Model G9-2, Digital Timer, Analog Timer, SERVICE Cont