Bunn FPG-2, LPG-2, G9WD, G2 TRIFECTA Funnel Sensing Coil Models MHG & G9-2DBC, SERVICE Cont

Models: FPG-2 G9-2T DBC G9-2 G2 TRIFECTA G9 G9WD LPG-2

1 79
Download 79 pages 39.46 Kb
Page 55
Image 55
Funnel Sensing Coil (Models MHG & G9-2 DBC)

SERVICE (Cont.)

Funnel Sensing Coil (Models MHG & G9-2 DBC)

FIG 62 FUNNEL SENSING COIL

Location:

The funnel sensing coil is located inside of the coil cover.

Test Procedure:

1.Disconnect the grinder from the power supply.

2.Remove the two 6-32 screws attaching the coil cover to the front of the grinder housing.

3.Pull slightly away from the housing and disconnect the two wires from the coil.

4.With an ohmmeter, measure the resistance across the pin terminals of the coil. The reading should be 5 to 7 ohms.

If this amount of resistance is not present, replace the funnel sensing coil.

Removal and Replacement

1.Disconnect the grinder from the power supply.

2.Remove the two 6-32 screws attaching the coil cover to the grinder housing.

3.Pull slightly away from the housing and disconnect

the two wires from the coil.

3.Remove the coil from the coil cover.

4.Place the new coil into the coil cover and attach the two wires previously removed.

5.Secure cover with two 6-32 screws.

FIG 63 FUNNEL SENSING COIL TERMINALS