Bunn LPG-2, G9WD, G2 TRIFECTA, G9-2T DBC, FPG-2 service manual Membrane Switch, SERVICE Cont

Models: FPG-2 G9-2T DBC G9-2 G2 TRIFECTA G9 G9WD LPG-2

1 79
Download 79 pages 39.46 Kb
Page 53
Image 53
FIG 58 MEMBRANE SWITCH

SERVICE (Cont.)

Membrane Switches (Models FPG-2 & G9-2 DBC)

FIG 58 MEMBRANE SWITCH

Location:

The membrane switch is located on the front of the hopper housing.

Test Procedures:

NOTE: Before continuing, check that the ribbon cable is properly connected to the control board and not a pin off in either direction.

1.Disconnect the dispenser from the power source.

2.Remove the rear panel and disconnect ribbon cable.

3.Check for continuity of the switches using pin #1as common.

A1

- #5

Grind

A2

- #6

Stop

B2

- #10

Hidden Button "Right"

C1

- #2

Large Batch Size "Left"

C2

- #3

Medium Batch Size "Left"

C3

- #4

Small Batch Size "Left"

C4

- #9

Large Batch Size "Left"

C5

- #8

Medium Batch Size "Left"

C6

- #7

Small Batch Size "Left"

 

- #1

Nuetral

If continuity is not present when the appropriate switch is pressed, the Membrane Switch must be replaced. If continuity is present, chech the short harness going to J6 on the Control Board.

Removal and Replacement

1.Disconnect the grinder from the power supply.

2.Remove the rear access panel.

3.Disconnect the membrane switch harness from the control board.

4.Carefully peel the membrane switch from the front of the switch bezel.

5.Remove any excess adhesive from the bezel sur- face.

6.Remove the backing from the new membrane switch.

7.Feed the membrane switch harness through the openning and apply the new membrane switch to the switch bezel.

8.Connect the switch harness to the control board.

To Control Board J6

 

 

SHIELD

 

 

 

 

 

 

 

 

11

 

 

 

 

 

1

B2

C4

C5

C6

A2

A1

C3

C2

C1

 

 

SWITCH UNIT ASSY

 

 

 

FIG 59 MEMBRANE SWITCH

53

41545 122209

 

Page 53
Image 53
Bunn LPG-2, G9WD, G2 TRIFECTA, G9-2T DBC, FPG-2 service manual Membrane Switch, SERVICE Cont