lowest intensity while “BRT4” is the brightest. Simply press the MODE button until the desired brightness setting is displayed and select by pressing and releasing the POWER button.

There are two ARC™ (Angle Range Compensation) modes and one REGULAR mode. The two ARC™ modes are

BOW mode () and RIFLE mode ().

To select between these modes, first turn the unit “ON” by pressing and releasing the POWER button. Next, press and hold the MODE button for three seconds to get into the SETUP menu. The brightness is displayed first and can be changed by pressing the MODE button or accepted by pressing the POWER button. Then press the power button until

you see the existing compensation mode indicated by either the “Bow” symbol ( ), the “Rifle” symbol (

) lit with

one of the ballistic groups (A thru J) displayed and flashing, or no indicators lit and the message (

) flashing.

The modes can be cycled through in a circular fashion by pressing and releasing the mode button. The order of modes is a follows: BOW, RIFLE A, RIFLE B, RIFLE C, RIFLE D, RIFLE E, RIFLE F, RIFLE G, RIFLE H, RIFLE I, RIFLE

J, REG, etc. When the bow selection is displayed, (

) will flash and when the rifle

selection is displayed, (

)

and ballistic group will be flashing. When the (

) is displayed, the message (

) will flash within the display.

Once the desired distance compensation mode is displayed, select it by pressing and releasing the POWER button. Following this selection, the current unit of measure, “Y” for yards or “M” for meters will flash in the display and the SETUP icon is still lit. Pressing the MODE button will toggle the unit of measure. When the desired unit of measure is displayed, press the POWER button to accept the unit of measure.

If the user chooses RIFLE mode, and after having determined unit of measure, the user has the following options:

1. Variable Sight-In (VSI™) - Allows the rifle hunter to choose from four sight-in distances (100, 150, 200, or 300 yards or meters) and provides holdover / bullet-drop data in inches, centimeters, MOA, or ML (mil). The “SD” (Sight-

In Distance) indicator will turn on and the current Sight-In Distance number will blink within the display (I.e. 100, 150, 200, or 300). The Sight-In Distance options can be cycled through in a circular fashion by pressing and releasing the mode button. Once the desired Sight-In Distance is displayed, select it by pressing and releasing the power button.

2.And finally, if RIFLE mode was chosen, and as long as unit of measure and a sight-in distance was selected, you have the option of determining how you would like hold-over / bullet-drop displayed. If measurement units are in yards, you will be able to choose between inches, MOA, or ML (mil). If measurement units are in meters, you will be able to choose between centimeters, MOA, or ML (mil). For example, the “CM” for centimeters or “IN” for inches will flash in the display and the SETUP icon is still lit. Once the desired ballistic measure is displayed, select it by pressing and releasing the power button.

Upon returning to the normal operating menu, the current compensation mode and unit of measure will be identified in the display as indicated below.

SETUP Menu

Normal Operating Menu

SETUP menu Normal Operating Menu

When the unit automatically powers down, operation will always return to the normal operation (i.e. away from SETUP) with the last used ARC™ mode active (i.e. BOW, RIFLE, or REGULAR) along with the last used TARGETING modes active (Standard SCAN, BULLSEYE, or BRUSH). If the unit turns off while in the SETUP menu, the unit will always return to the last mode(s) still active.